  1. Ydel

    NMS on CallPilot

    Thanks allecmac for your response. I looks like I have to get Pkg 175 in site B. Do you know of other documentation other then 555-7101-302 to implement this feature. Thanks
  2. Ydel

    NMS on CallPilot

    I will be implementing NMS with CallPilot 201i for a customer site. My question is after reading documentation and engineering guide, I believe that if I have site A that has a CallPilot server (prime site) and site B (satellite site) with sip trk with D channel connected using CDP, that would...
  3. Ydel

    CPPM RLS 5.0 IN OPT 11 NTDK11 CABINETS

    Thanks 9210. I am planing to use one at the customer. After tacking to a few teck’s yesterday, I seem that the Loadware MGCCAD46 is older. So I will replace it with MGCCAH17 and I am told that it should fix the problem. Thanks again.
  4. Ydel

    CPPM RLS 5.0 IN OPT 11 NTDK11 CABINETS

    I think after looking through all Nortel bulletin, I found the MGCCAH17 that I don’t have loaded. That may fix my problem. I would still appreciate your comment if you had this problem. I still have to try it a customer site.
  5. Ydel

    CPPM RLS 5.0 IN OPT 11 NTDK11 CABINETS

    Has anyone upgraded Opt 11 cabinet with NTAK11 to Rls 5.0 using CPPM C/S & S/S with MGC’S NTDW61BAE5 96 DSP (DB96 in position 1) tn 11,12,13, on both. My problem is that I have 2 cabinets NTAK11 at the customer site with PRI in slot 6 in the 1st cabinet. At this time we are not connected to...
  6. Ydel

    CallPilot 3 digit mailbox

    Thanks guys. I went and changed the password length and some reason it let me program 3 digit mailbox. Never cease to amaze me. Thanks you guys for your responce.
  7. Ydel

    CallPilot 3 digit mailbox

    I have a system that is migrating from Meridian Mail to CallPilot. The Merdian Mail has 3 digit lengths MailBox. I have migrated the Mailbox to CallPilot but when I go to greater a new MailBox in CallPilot with 3 digits, it is giving me a error that the mailbox length has to be 4 to 18 digit. I...
  8. Ydel

    TRAFFIC STUDY ON PRI TRUNKS

    Thanks for you responce. I will give it a try today.
  9. Ydel

    TRAFFIC STUDY ON PRI TRUNKS

    Can anyone tell me if it’s possible to do a traffic study on 2 PRI spans. In LD 2 should I set a report for trunks. Would that capture PRI information. THANKS
  10. Ydel

    IP Peer Networking

    Thanks dlesap. I have window to restart the Sig Server next week so I will give it a go. One more point that I,m not clear on. Does the Sip Domain Name have to be the SAME in all 3 Sig Server and the Sip Gateway Endpoint Name is the name of the Sig Server at that specific site. Thanks again.
  11. Ydel

    IP Peer Networking

    Thanks dlesap. CS Virtual routes are good. They are working fine between the Alternate and Failsafe using 4 digit CDP. I did some more reading after you mentioned Dynamic registration and found it in (IP Peer Networking) NTP's Should I be following the (Enabling and Configuring the NRS server in...
  12. Ydel

    IP Peer Networking

    I am implementing IP Peer between 3 sites with SIP. I have 2 site configured with Virtual TRK &D channel. I have these sites working with CDP without NRS implemented. They are configured as Alternate and Failsafe. I will be adding the main site witch will be the Primary and the co-resident NRS...
  13. Ydel

    Moving a supperloop

    Thanks again.
  14. Ydel

    Moving a supperloop

    Thanks John. From you suggestions, being an 81C to you think that moving 1 card at a time ( 24-0-1) is possible instead of moving the loop (24-0). Being supper loops I am a little confused with the (STUN) prompt in LD 25 where it says, The source card must NOT Be on a supper loop; the...
  15. Ydel

    Moving a supperloop

    Can anyone tell me if I can move a supperloop (LD 25)? to a new supperloop. Example: Moving supperloop 24 to make room for new DDP card PRI 24 & 25. Want to move supperloop 24 to an new supperloop 20-1. Already have 20-0, by reusing the IPE shelf from loop 24. Just have to move the ENET cable...
  16. Ydel

    Call Pilot MWI Light

    Was this a migration and if so do you still have Meridian Mail AML still active??????
  17. Ydel

    Programming 1140E ip set

    Thank dlesap I will run with that.
  18. Ydel

    Programming 1140E ip set

    Has anyone programmed a 1140E ip set. Cant find the right document for set type in LD 11. The 1140E set is no a choice, and the i2007 set is not there either. I used i2004 for the i2007 set type and seem to work ok.???? Thanks. TYPE: ? 2003 2006 2008 2009 2016 2018 2112 2216 2317 2616...
  19. Ydel

    Caller ID - non PRI - again

    In my opinion,I think you need PRI and more so you need a D channel. The out going number should be controlled by the PBX CLID created entry in LD 15 and the out going name should be sent out by the CO office. Attendant console uses LDN0 digits and CLID entry 0.
  20. Ydel

    IP set re-register more often then others

    Since we installed our IP sets, we've been seeing that the vast majority of our IP sets need to re-register with the signaling server very frequently. While the sets re-register, calls cannot be accepted nor initiated (lasts about 20-30 seconds). Initially, we thought that our DHCP lease time...