Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations wOOdy-Soft on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by wayneled

  1. wayneled

    IA770 cannot transfer from mailbox

    Thanks for the reply the extension i am transfering to is a subscriber. it's an ia770 in a stand alone s8500c. extension is local. the problem doesn't happen if the customer is at this desk, calls vmail, logins in, then does *t. so it is some sort of restriction in the pbx. the trace is not...
  2. wayneled

    IA770 cannot transfer from mailbox

    after logging into my mailbox,i hit *t, am prompted for extension number, i enter number followed by #, hear the name announced, told to please wait. then i get "transfer cannot be completed" i can transfer out of an AA,and *t from a greeting. enhanced cover 0 set to yes. no operator...
  3. wayneled

    IA770 with S8300 and CM5

    start -ac
  4. wayneled

    Intuity LX remote access error message

    When using dialup to an LX, after logging into the web browser with sappp, and after opening messaging, then logging in with sappp, i get a "could not change to home directory" error message and can't procede. any ideas, or know how to use ASA to access? (port 23 doesn't work) thanks
  5. wayneled

    BCMR V2.4

    you are correct. just ignore the error message and it works. I wasted a lot of time on that one. lol thanks for all repsonses
  6. wayneled

    IA770 on S8300

    give a shot a busy/release the trunk group is the signal group in service?
  7. wayneled

    BCMR V2.4

    all the above docs refer to pre-rel CM4. the problem is that when the server tries to connect to the pbx, I get an error that the BCMR login I made with prof18, doesn't have the right permissions. the docs all refer to CM3 or below. not any help with the new way to add logins with R4 the...
  8. wayneled

    BCMR V2.4

    any luck with this?
  9. wayneled

    ASA dadmin login 4.0.1

    to my knowledge, no.
  10. wayneled

    S8300 9600 phones keep getting DHCP conflict

    i don't mean ping the phone. if you know the ip address of the phone and its working ok, then you get the dhcp conflict error, unplug that phone, and ping the ip address it had. you shouldn't get a response since you unplugged the phone. if you do get a response, the address is assigned to...
  11. wayneled

    Limitations of Definity Prologix

    Prologix where availble with two offers, A and B. not ever circuit pack that worked in B worked in A. it sounds like you had a B, but maybe when you loaded license file for additional RTU, changed it to A.
  12. wayneled

    Outcalling alarms to cell phones

    i think you would be able to do this two ways, neither simple. 1) use smnp traps on the LAN to monitor alarms. Have that program that monitors the LAN outcall. 2) use the contact closure on the IPSI cables. connect them to some 3rd party device that would outcall when contacts are closed.
  13. wayneled

    Cant access web interface for gateway

    what do you get when you try to login? a 404 error?
  14. wayneled

    update_unpack failed

    i use IE6 to download files, i just delete the brackets. the install wizards don't work too well with IE7.

Part and Inventory Search

Back
Top