Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations TouchToneTommy on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by snavalgund

  1. snavalgund

    Incoming calls not getting released

    Can you be more elobrate on the Protocol A Shridhar Navalgund
  2. snavalgund

    Incoming calls not getting released

    Incoming calls not getting released. I have Definity System of version R8. I have also interfaced a ISDN-PRI link from the service provider who has a 5ESS switch. The problem is that sometimes when the definity recieves a incoming call these calls donot get released inspite the caller...
  3. snavalgund

    I have a Definity G3R of version R6

    Thnx for all that .... i gave a power on restart and the problem got resolved.. Thx for all that Shridhar Navalgund
  4. snavalgund

    Nice log recording system to Definity

    Can I also have copy ... snavalgund@vsnl.com thnx.... Shridhar Navalgund
  5. snavalgund

    I have a Definity G3R of version R6

    I have a Definity G3R of version R6 load 246........ i have 9 EPN's on it and also 3 announcement boards... my problem is that i am unable to record new ANNOUNCEMENTS.... I have done the following things System... Critical Reliable Console permission given to the Recording Extension. New...
  6. snavalgund

    Craft Level Password

    That is true that for R8 and above there is a challenge that is asked even for the craft login and controls the permission....... i presume this was basically done to have control on the licences -- RTU .. Shridhar Navalgund
  7. snavalgund

    Craft Level Password

    There has been a quite long thought given to the levels of logins and ther permissions associated to it. Have this one. Systems R6 and below were available. Login :- init ( only with avaya to do the RTU,S ) Login :- inads ( Super- user login that gives the highest permission on...
  8. snavalgund

    I have received procesor DefinityV9

    Let me know what system was this previously or is it a new purchase.Because if it is old version system and you are trying to insert the new R9 processor , you will get this problem, it will not allow you to save the translations. Contact the Avaya immediately. Shridhar Navalgund
  9. snavalgund

    I want to know more on DS1 Remoting

    Thks all of you all. Shridhar Navalgund
  10. snavalgund

    I want to know more on DS1 Remoting

    I want to know more on DS1 Remoting EPN? What are the features it supports? Maximun number of ports it will support on EPN? Is it a reliable way of doing it.?Pls put in your experencies on it if you have any in you network? Thanks Shridhar Navalgund
  11. snavalgund

    Call Center Pick-up group

    Hey guys it affect the BCMS reports badly, the SLA dips down.If you go through the Documentation on the BCMS reporting the Call Pickup is a Void condition in the Call center sceniro. Shridhar Navalgund
  12. snavalgund

    To interface definity to BT board on ISDN -PRI

    Thanks Edvin, Can i have more info on the Avaya conversion of DPNSS to Q-sig? where can i get it. Any PEC codes fot it ? Shridhar Navalgund
  13. snavalgund

    To interface definity to BT board on ISDN -PRI

    I have Definity Prologix R8 system and i want to interface a BT ( British Telecom )dealer board equipment on ISDN-PRI. It is not happening ...someone pls guide ... help Shridhar Navalgund
  14. snavalgund

    Call coverage off net then back to PBX for VM

    Yes we can get the call back in the PBX once routed fron the remote coverage to POTS .This can be done if you have ISDN lines interfaced to the PBX and during the remote coverage path the system picks up these ISDN line to dial out the POTS . It can then jump to other points defined in the...