Hi folks,
Can anyone point me in the right direction as regardsprogramming new i1100 series sets? Programmed as a type i2004 per chance?
Thanks,
Patrick.
Nice one, thanks guys, that worked.
Normally it would have been one of the first things I'd have tried but what with the PBX reporting problems with relocations and wrong set types.
Kind of throws you off track when you get rubbish SCH codes like that.
Hope everyone enjoyed their turkeys by...
Did a PRT of the SRDT but got no results.
Tried a CHG on 036 14 but getting SCH2501 - An attempt was made to change a telephone that is in the process of relocating.
This is definitely corruption on the switch. Will try the EDD and Sysload.
Thanks again everyone.
Correct. I cannot either CHG, PRT or OUT the TN.
This is an option 11 and I seem to remember a corruption problem with relocation.
I will try a PRT of the SRDT in LD 21 when I get a chance and this may point me in the right direction.
Thank you everyone for your help.
I did a PRT of the TNB on that card and it skips from 36 13 to 36 15. There is no mention of 36 14. I would take this as meaning that it is a free TN.
Corruption maybe?
I did a stat on the card and came back with
Unit 14=DSBL (2317)
Unit 30=UNEQ
When I try and PRT the TNB for that TN I get
No ACT since no date
Any more ideas guys?
I'm using TN 036 0 00 14. There are 6 of the 2006 type sets programmed on other units on the card including unit 00. I tried programming a 2006 on unit 14 just as a test and got the same sch0807.
Make sense?
The new i2033 sets are programmed as i2001 sets. The only thing you have to be make sure of when programming is that you have HFA (hands free allowed)in the CLS.
If you need the commands please reply asking for them.
Is it possible that the output format of the CDR was changed to the NEW or 3-line format (they are both the same thing but it depends on what part of the world you are in)?
If so you will have to get your call accounting software profile changed to match what is now being output on the CDR...
Hi,
I'm trying to program a new 2616 on a particular free TN but am getting sch0807 - TN is valid but unable to match type. Anyone got any ideas?
Thanks.
You would still be performing an ECHG on an ACD set to null the key in the first place though so that would be adding an unneccessary step to the process.
I have found that as long as you deaquire the set from Symposium before doing the ECHG or CHG then you shold be ok.
Also make sure to remove any BFS keys on sets monitoring this TN and remove the DN from any hunt groups.
You need to purchase additional licesnes to add in more sites. PhoneMaster is licensed on a per PBX basis.
Your best bet is to contact them direct to find out how you go about this. Their toll free number (according to the web) is 1800 660 9248.