Well, what I ended up doing was assigning principal user for 806 (the line in question)to 133 (bell). 133 has no coverage assigned, so now 806 will ring forever, which is what they wanted. Good enough for me.
I have a line that, as far as I know, is only assigned to two extensions, 115 (dispatch phone) and 133 (bell). When someone calls in on this line, after a few rings it goes to the voicemail for extensions 100 (which is an operator). I don't believe this line is any pools. So far I have tried...
DCIU integration requires a processor interface channel. Prologix bus architecture does not provide for a processor interface card to be installed. No processor interface card, no processor interface channels. No processor interface channels, no DCIU link.
Much easier, but unfortunately on a G3v2 running as G3v1.1, not available. I went through the process described above with the customer and it worked like a charm. This round's on me. Thanks again 1a2.
That's the part I was missing, the cov-msg-rt button. Tried it here in the lab and it worked great. Waiting for customer to get back to me regarding this. Thanks!
I am just wondering if anyone knows how the Leave word calling (LWC) "Stations with System-wide Retrieval Permission" on the system-parameters features form works. I understand that this can give display phones access to retrieve LWC messages for non-display phones, but on the display phone I...
I have tried this. I had the attendant do this from the attendant console. "attd" was added to the global LWC receivers but when I had the attendant try to enter the LWC cancel FAC it did not work. The attendant does have a COS with console permissions.
Transfer directly to voicemail is only available to be used by a station that is part of your coverage path. Say Bob has a secretary and Bob's coverage path goes to his secretary first, and then voicemail. When the secretary answers the coverage call coming from Bob's phone, she can then hit...
I have a customer with an old G3v2.2 tape system that previously had a display set Definity AUDIX 3.2 in it. This system failed and as a replacement they had a Definity AUDIX 3.2 with control link installed. There were a few stations that had the leave word calling messages still on them from...
When I run "set time" I change time from "standard" to "daylight savings". When I try to enter this, it says I must verify the date/time. I re-enter date and time but it still says this. Is there another setting I need to change? I have setup the daylight savings rules and set the set time form...