Brian
You can use the MML command "SUSIP:DIR=XXXX:", where XXXX is the virtual freeseating number. By using a suitable comms program for MD110 administration, you could edit and compile a text file, filled with commands to list the status of each of the virtual numbers in turn to give you an...
On the TLU76/13 board there is the single RJ45 connector. Pins 1&2 are the receive (Rx) and pins 4&5 are the transmit (Tx). Before trying to hook it up to the freeset system, ensure that you can clear the fault code 269 by applying a loop towards the TLU76/13 Board. Just get a standard spare...
Hi Ole
What response do you get if you run "IODDP;"?
What result do you get if you run "FIFTI:SUBFS=SAFETY-SF;" ?
Are you sure that the SCSI bus connecting the drive to the NIU board is electrically 'terminated' correctly ?
Regards,
gedii
Hi,
Wonder if anyone can help me ? I have an AAU2 board configured for SNMP. I believe I have configured everything correctly and all works fine in that the alarms genberated by the MX-ONE (TSW) are received by the Network Management application. The problem however is that after a number of...
Hi dgcm
The upgrade to Version 9 will pose no problems to the operation of a Mk5 Ops console, there are no fundamental compatibilty issues to be considered.
Rgds, gedii.
Yes, your understanding of the circuit pairs is correct. I thought I might have confused the issue a little. I think I'm right with the RJ45 side of things but I was going on memory and theory rather than checking a working installation. Please excuse any error here if you do find in fact that...
For any interested parties, the HiPath DX (Realitis)electronic manuals can be browsed on-line at the following URL:-
http://hipath.custhelp.com/DX_files/HiPath_DX_EP_V9new/EP%20v9.0/index.htm
Regards, gedii.
Hi
You will need either a TSR 901 0450/11000 (8 pair) or a TSR 901 0492/11000 (16 pair) cable from the front (bottom) of the TLU79. Terminate this on Krone strips as normal (ie: white/blue, white/orange etc). ISDN circuit 1 (Individual 0 ) will be presented on pairs 1 & 3 (RX & TX), Ind 1 will...
Kank
Thankyou for your suggestion. I had considered a solution along these lines and am not rejecting one but was just hoping for something a little tidier (eg: patch etc)
Regards
gedii.
Hi
I am using a CTI application via Applink on a 1-LIM TSW MX-ONE (SP5) and have a need to identify internal callers from what they are dialing as well as their extension number (CLI). One way is to use empty Hunt Groups which have CDINI diverts set to a CTI enabled ACD Group and Applink. This...
Hi
Could somebody please advise me of typical "RODAI/ROCAI" settings to connect to a BT ITS Dealerbaord, using QSIG (TLU76/1) ?
Also, could you advise of the "colour" code of the ROF 901 0481 cable in terms of the Tx/Rx and also what colours need to terminate on what pins of an RJ45 connector...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.