Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations TouchToneTommy on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: gedii
  • Order by date
  1. gedii

    How to list free seat numbers

    Brian You can use the MML command "SUSIP:DIR=XXXX:", where XXXX is the virtual freeseating number. By using a suitable comms program for MD110 administration, you could edit and compile a text file, filled with commands to list the status of each of the virtual numbers in turn to give you an...
  2. gedii

    TLU76/13

    On the TLU76/13 board there is the single RJ45 connector. Pins 1&2 are the receive (Rx) and pins 4&5 are the transmit (Tx). Before trying to hook it up to the freeset system, ensure that you can clear the fault code 269 by applying a loop towards the TLU76/13 Board. Just get a standard spare...
  3. gedii

    Failed to reload from Safety backup

    Hi Ole What response do you get if you run "IODDP;"? What result do you get if you run "FIFTI:SUBFS=SAFETY-SF;" ? Are you sure that the SCSI bus connecting the drive to the NIU board is electrically 'terminated' correctly ? Regards, gedii
  4. gedii

    AAU2 Board - SNMP application stalling

    Hi, Wonder if anyone can help me ? I have an AAU2 board configured for SNMP. I believe I have configured everything correctly and all works fine in that the alarms genberated by the MX-ONE (TSW) are received by the Network Management application. The problem however is that after a number of...
  5. gedii

    Mk4/5 Ops Console - with newer software version

    Hi dgcm The upgrade to Version 9 will pose no problems to the operation of a Mk5 Ops console, there are no fundamental compatibilty issues to be considered. Rgds, gedii.
  6. gedii

    help

    Yes, your understanding of the circuit pairs is correct. I thought I might have confused the issue a little. I think I'm right with the RJ45 side of things but I was going on memory and theory rather than checking a working installation. Please excuse any error here if you do find in fact that...
  7. gedii

    DX - Electronic Manuals - thread964-1457439

    For any interested parties, the HiPath DX (Realitis)electronic manuals can be browsed on-line at the following URL:- http://hipath.custhelp.com/DX_files/HiPath_DX_EP_V9new/EP%20v9.0/index.htm Regards, gedii.
  8. gedii

    help

    Hi You will need either a TSR 901 0450/11000 (8 pair) or a TSR 901 0492/11000 (16 pair) cable from the front (bottom) of the TLU79. Terminate this on Krone strips as normal (ie: white/blue, white/orange etc). ISDN circuit 1 (Individual 0 ) will be presented on pairs 1 & 3 (RX & TX), Ind 1 will...
  9. gedii

    DNIS numbers - Access internally and via DPNSS.

    Kank Thankyou for your suggestion. I had considered a solution along these lines and am not rejecting one but was just hoping for something a little tidier (eg: patch etc) Regards gedii.
  10. gedii

    Executive override

    Hi FlavioMiranda You need to clarify exactly what you mean by cancelling "Executive Override" ? Regards gedii
  11. gedii

    DNIS numbers - Access internally and via DPNSS.

    Hi I am using a CTI application via Applink on a 1-LIM TSW MX-ONE (SP5) and have a need to identify internal callers from what they are dialing as well as their extension number (CLI). One way is to use empty Hunt Groups which have CDINI diverts set to a CTI enabled ACD Group and Applink. This...
  12. gedii

    Trunk Monitoring on Application Link

    Only the following may be monitored via Application Link: analogue, digital, cordless or CAS extensions, ACD/CTI groups. Regards, gedii.
  13. gedii

    BC12.1 QSIG connection to BT ITS Dealerboard

    Hi Whosrdaddy, The system is at BC12.1 (SP9) GB. Is that enough info ? Thankyou for the RJ45 detail in the meantime. gedii.
  14. gedii

    BC12.1 QSIG connection to BT ITS Dealerboard

    Hi Could somebody please advise me of typical "RODAI/ROCAI" settings to connect to a BT ITS Dealerbaord, using QSIG (TLU76/1) ? Also, could you advise of the "colour" code of the ROF 901 0481 cable in terms of the Tx/Rx and also what colours need to terminate on what pins of an RJ45 connector...
  15. gedii

    nscoi

    Hi Afterthought.....where I've stated "NANSI/NANSE", read "NASCS/NASCR". Regards gedii
  16. gedii

    nscoi

    Hi You can configure up to 30 EQU positions to "ring", upon a call Night Switching. These EQU positions are specified by the "NSCOI:EQU=xxx-x-xx-xx;" syntax and listed via "NSDAP". They can typically be ELU22/29 ports. Any phone can dial a code to pickup an incoming call and calls can be queued...
  17. gedii

    Optipoint 500

    Hi mattyjenks As far as I know, there is little charge if any and there are no "end-user" licencing constraints. Once installed however, I think the onus is pretty much placed on the "customer" in resolving any problems arising (ie: Ongoing support is limited due to the application generally...
  18. gedii

    Outgoing DDI numbers

    Hi If you haven't already acquired a fix for this, then have a look at System parameter "SPEXN" within the DX ? This is listed by typing "LSSP SPEXN" in MMI. If it is set as a 0, the "DDI" number of the extension will be given regardless of EXD. If set as a 1, the main published number will be...
  19. gedii

    High call rate

    Hi, if this is Multi-LIM MD you need to look at the basic engineering of the system in terms of routes, extensions and operators, as your customer will be experiencing some degradation to service and it is pointless to try and "mask" the alarms. Is there a reasonably even distribution of...
  20. gedii

    Optipoint 500

    Hi The USB port on the Optipoint 500 (basic, standard & advance models) is for connection to a PC in the main. There is a Siemens TAPI application called "Uniclient". This brings control of the Optipoint phone to the PC (via USB) and looks rather like a VoIP PC soft Client to the eye. Uniclient...