Hello Patty
This pc is part of a W2K domain, multiple users log to the computer and it is supposed to be configure so the screensaver will load after 10 mins. This is to all users.
I need to know how to apply it to every user.
Thanks, D
Hello I need to apply folder permissions to a user group on a W2K domain as follows:
1. The user will be able to write to the folder.
2. After the file is saved then it cannot be deleted by the same user.
In other words I want to write but then not delete or rename the file.
Is this possible...
Hello
I need help to fix a problem for a HP-UX using strong-hold and cgi-bin for logging. The server does not recognize the username and password even though they are the correct ones.
Any help.... please
Diny
Hello
I am trying to set a local user policy to restrict most of the folders and programs, because the workstation will only work with Excel 2000. I did manage to apply this policy but it only works using Local Group Policy and even when I log as administrator the policy is in place and I am...
Hi
Just a quick note, the area code 809 is a legitimate area code and it belongs to the country Dominican Republic. In the past and now some scams occured with this area code.
Please review these links:
http://www.breakthechain.org/exclusives/809.html
http://www.scambusters.org/809Scam.html...
Hi
No, I need to know how to program the switch or MM to recognize both 4 and 5 digit extensions and mail boxes.
This is for new extensions, the 4's will remain the same.
Thank you!
Safe Shutdown Procedure:
1.Do a System Backup
LD 43
.EDD (hit enter and wait 1 or 2 minutes till it finishes)
2.Meridian Mail Backup
1.At the Main Menu Select option 1 General Administration
2.Select option 2 Volume and Selective Backup
3. Highlight with the spacebar VS1 and VS2 and...
Hello
To view all available extensions numbers
>LD 20
REQ: PRT
TYPE: LUDN
CUST X (X is customer number)
DN (hit enter and the list will start)
To view all used and ununsed TN's (analog)
>LD 20
REQ: LUU
TYPE: 500
CUST X
(hit enter)
To view all used and ununsed TN's (digital)
>LD 20
REQ: LUU...
hello
I need to setup a Banyan client to print to a network printer (NT Network). Specifically HPLJ8000.
Also anyone knows how to "sniff" in a NT network a Banyan VINES server?????
Thank you!!
;-)
Hey try this conf with Procomm
WYSE 75
7-N-1
Zmodem
9600 bps
or
VT320
7-N-1 or 7-E-1
Kermit
9600 bps
Hyperterminal should connect using:
VT100
8-N-1
9600 bps
But if you need to connect to MM.... hyperterminal will not work properly.
good luck [thumbsup2]