I put it into SIP using the phone boot menu. Trying to web into it in order to put in the credentials and target for a SIP server
If you haven't failed at some point, you're not trying...
Not seeing the 5330e reach out to the server, manually configured TFTP address under network IPV4 parms. Went back and changed manual update, confirmed. No activity to the server. Out of curiosity, I changed the phone to Minet, and saw this on the TFTP log viewer:
Connection received from...
Have been into a Mitel 5330e phone before, by setting SIP mode , identifying the IP and browsing to it. Have read all of the dead-end posts, except for one that states they found the magic .bin file to enable the web interface. (sip5340ttnlang_en_US.bin). I have looked MOL in IP endpoints...
Thanks for the prompt response. I appreciate it. Wasn't sure if it needed any conversion- I will test next week when we return to "tweak" the install. I will post if we need to go through the PMS options screen.
if you haven't failed at some point, you're not trying...
Original cable from SX-200 was terminated with an 8 pin connector. (Picked up on this install after the fact). I need to put a male db-9 (RJ45 to DB9) for the Precidia, and RJ-45 to DB-25 male at the other end for the OPERA system server.
if you haven't failed at some point, you're not trying...
Replacing an SX200 and installed 3 Precidia IP adapters to integrate the new 3300. What are the pinouts for RS-232 adapters? The PMS is HI Opera, and has an "Octopus" with DB-25 female connections. I found the port info and have tested SMDR output at least, and it works to my laptop. PMS company...
phonetech1, what did you do to get it working? I have a customer getting ready to activate SMDR & call accounting. I set up the login string & password, but it's not connecting via SSH to port 44000
I have those in place. If I call the DN 547 directly, it goes to VM (400). If it rolls to it as the AODN from the console, it rings about 8 times & returns to the menu from where it originated. DID to voice service, CL option 1 to Attendant (190) LDN. console rings, overflows to 547, reverts to...
I am picking up where someone left off, and need to set up an attendant overflow, then to voice mail. I have the overflow working, but the forward to Vm on the overflow DN is not working. I can post the PRT of ATT & the DN's
Option 11
AODN 547
547 has hunt 400 AND a key showing CFW 4 400
If you are using Session Manager, go to Devices/Page Zones on the left, on the right, right click and create a zone, double-click the zone, add either keysets or trunks (for valcom type equipment)
I just set it to Yes, and couldn't take the day off. Get a busy when calling ACD 501. I tried it as an overflow too. No change. Someone suggested I set up a dummy ext & fwd to VM, with a vsdn matching but a TD type. Still not working.
Basically, how would I set up the auto attendant to answer...
I am having nite mode issues. The VSDN no longer answers in night, so I sent the NIT target to another set to be answered. I have looked at the VSDN, 190 which matches the LDN on the console, TD table 902, Announcement DN 900 & 901 (Day-Night). Tables are OK, Greetings exist, but the target VM...
I disabled all cards & moved the first TMDI card to slot 3, since it has the Clock control daughter on it. I re-enabled and moved clocking to card 3.Why it worked before, I don't know. All the old programming was left in. It's working for now...Thanks for the replies
Since a hard reset to correct a VM down, the PRI in an Option 11 is bouncing- RLS RED ALRM, RLS CTS DOWN, EST CONFIRM. every 3-5 minutes. I think the last changes to remove 2 T's and start the PRI may not have been saved, but it was done by a previous tech, who is no longer available. I'm not up...