Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations wOOdy-Soft on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by bostech

  1. bostech

    BCM450 BFT Replacement

    I know exactly what your talking about regarding the dust. I've seen dust accumulate over LEDs so thick that you can't see the LED lit. One more question, it's been a very long time since I've had to regenerate a keycode. I don't need a migration auth code to regenerate a keycode as long as I...
  2. bostech

    BCM450 BFT Replacement

    Firebird, Incidentally, this system is a BCM400 upgraded to a 450. Would the PS cause such an odd and isolated problem? CurlyCord, No Alarms at all. Green LEDs.
  3. bostech

    BCM450 BFT Replacement

    Thanks CurlyCord. I appreciate the info. Firebird, Thanks for your inquiry. My customer's BCM is having IP connectivity problems on the two LAN ports. The system is networked with two other systems. Site to site calling doesn't work and the BCM can't be pinged. Can't connect to the BCM with...
  4. bostech

    BCM450 BFT Replacement

    Hello All, I'm looking to replace a BFT in a BCM450 R5. Does anyone have any experience with this? From what I can gather, I'll have to regenerate the keycodes to the new System ID and I should be able to restore the config from a backup. Any insight or advice would be appreciated. Thanks
  5. bostech

    Analog Line Echo/Squeal

    I had a very similar issue a couple of months back. 4 analog lines coming from a Comcast voice modem to an IPOV2. Audio was cutting in and out through the digital phones. It got progressively worse as you took more lines off hook. Lines were simultaneously tested directly from the modem using...
  6. bostech

    Analog Line Problem

    Mkoker, you sir get a star. The filters from The Sandman worked. Thank you for the suggestion.
  7. bostech

    Analog Line Problem

    Well, Comcast replaced the voice modem with a brand new one yesterday with no improvement. Every piece of hardware has been replaced. Not sure where to go with this.
  8. bostech

    Analog Line Problem

    Thanks Mkoker. I'll take a look at them.
  9. bostech

    Analog Line Problem

    Hello All, I have a head scratcher here. System is an IP500V2 R9.1 w/ 1 Combo Card running in basic mode (I know). 5 9508 sets and 4 analog lines. Comcast is the carrier. Just installed about a month ago. All new equipment. Control Unit is grounded. Problem popped up a week and half ago...
  10. bostech

    Softphone Compatibility

    Thanks Firebird. Appreciate the quick response.
  11. bostech

    Softphone Compatibility

    Hello, Does anyone know if there would be a compatibility issue with running a 2050 R2 softphone with a BCM R5 or R6? Thanks
  12. bostech

    Need Help Setting Up Info Line

    Use generic actions and specify a wav file to be played for each action.
  13. bostech

    IP Office 500 V2 7.0 Rebooting

    I had this exact issue with an IPO running 6.0 in Partner Mode. I upgraded to the latest 6.0 release, upgraded to R9, reformated/recreated the SD card, defaulted and reprogrammed from scratch. Nothing seemed to work. I ended up replacing the control unit. No more reboots.
  14. bostech

    BCM450 R6 Hard Drive Replacement

    UCX, Thanks for the reply. I like the idea of cloning the HD. Is there a particular brand I should use? Thanks
  15. bostech

    BCM450 R6 Hard Drive Replacement

    Hello All, A customer of mine is requesting that I replace the HD in their BCM450. They've had the system for a number of years and they're worried about the HD failing. They experienced this with a BCM400 in the past. Is it simply taking a backup, install the new 450 R6 drive, and restore...

Part and Inventory Search

Back
Top