Eddie,
I highly agree. We just took this course as a shop and what a diffence it has made in troubleshooting. By the way this class is only offered for onsight. Zac is a very good instructor. "Isn't this exciting?
Here is the dialing string *82 XXXX. This will then submit the digits. On another note am not sure if *82 will do anything if this needs to be set up or is a built in feature. Trying to soak up as much info as I can and learn as quickly as possible as we are turning up more and more users on...
We have a Fluke Smartpro used for ANI for our techs. We have some phones that are suppressed which do no delliver this and the tech needs to dial *82 for the smartpro to repeat back the DN. I have mainly worked on DMS equip and in one of our tables we designate what the * and # are but can't...
We have an OPT 61C rel 3.0 and have found out that we can't use the * or # keys. When pressed they send you to an announcement. I am new to the 61 world so from what I have researched what I need is OPAO (pkg 104) when I go to ld 22 and prt this pkg it says restricted. Does this mean that I...
We just had a OPT 61c rel 3.0 installed and is a remote off of our SL-100 and it is like trying to learn to ride a bike again. The 100 is all menu driven and also has alarm bars to visually indicate trouble and is specific to these areas (i.e. cpu/trunks/lines/i/o devices...etc.) but it has...
Hello All,
We have recently installed an OPT 61c rel 3.0 that is a remote off of our SL-100 and are trying to configure/purchase/come up with a way for our techs to ID lines in the field from the 61. The contractor that installed this tells us that this does not exist. There are 2 PRI trunks...
John,
Let me make myself more clear. 911 is not an issue since it does not leave my SL-100. We have a whole 10,000 block from Qwest (i.e 783-0000 to 783-9999) We have taken the 8-9000 range and given those number to our 61. We will be tied to the 61 via 3 PRI trunks. We want to use the 61...
We are (still) installing an OPT61c succ 3.0 which will be a remote off of our SL-100. It was brought to my attention yesterday that in the case of emergency this 61 will not be able to handle outgoing calls from my SL-100. (calls originating from my SL-100 and needing to get to the world) Is...
COuld someone tell me the loop lengths for an analog/digital/and isdn phones for a OPT 61C. We are getting one installed in a few months but have no books yet.
Thanks
We have all been there John ... The frustrating part is when you are in a translations course and 1/2 of the students have never logged on... Then you are like what R U doing here then.. switch 101 was last week. This happened in my sl-100 trans class had 5 out of 9 students that wanted to see...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.