Does anyone one know of the maximum speed on the RS-232 DTE and DCE serial cables. I have two 2500 series routers connected back to back with the DCE side clock rate at 148000. Anything over that, the line goes down. Is 148000 the maximum speed for that cable or do i just have to mess with the...
Ok heres the case. I have 2 2500 series routers connected via serial ports. One is DTE the other is DCE. Iam using PPP as the encapsulation. The thing is that I have the clock rate set at 148000. That gives me transfer rates between the routers at about 136kbs. Now if I try to increase the clock...
Hi Erik,
RouterA#sho cont se 1
HD unit 1, idb = 0x1197DC, driver structure at 0x11FB68
buffer size 1524 HD unit 1, RS-232 DCE cable
cpb = 0x23, eda = 0x940, cda = 0x800
RX ring with 16 entries at 0x230800
RouterB#sho cont se 1
HD unit 1, idb = 0x1E0D28, driver structure at 0x1E8388
buffer...
Thanks, I tried the slower clock rate but it still goes out after about 30 seconds. Plus you can only set clock rate on the DCE side.
I tried debug serial interface, this is what I got.
04:24:04: HD(0): New serial state = 0x0600
04:24:04: HD(0): Cable is unplugged.
04:24:04: HD(1): got an...
Hi Everyone!
What Iam trying to do is to connect two routers via serial ports. I followed instructions from cisco..
http://www.cisco.com/warp/public/116/hdlc_back.html
I did everything the way they said but the connection does not stay up. Right when I finish configuring the the second router...