I want to change a DCH from USR to NET, but in LD17 the prompt SIDE doesn't come up.
What mnemonic do I have to enter to make the SIDE prompt to appear?
This is an ageing CS1000M v7.6 After a power failure and reboot, it lost connection to 2 sites both in the same Dual PRI card. After some reseting of one of the loops it recovered, but the other refuses to link. The "remote" system is 15 feet away connected with a factory issue db15-BNC cable...
I have a 6509 acting as a distribution switch, one of the downliks is an old FO to a small site which every now and then has a small interruption that cause the whole network to recalculate the spanning tree, so I disabled stp on the access switch (Yeah I know cisco blasphemy) and set the link...
I am trying to diagnose an MGC card (CS100E linux). At the oam> prompt Does the command dsphwcheck have any negative impact on the system (reset, downtime, etc)?
Good Morning every1
In what LD do I change this:?
CALL REF # = 17289
BEARER CAP = VOICE
HLC =
CALL STATE = 10 ACTIVE
CALLING NO = 78011 NUM_PLAN:UNKNOWN TON:UNKNOWN ESN:UNKNOWN
CALLED NO = 89178440 NUM_PLAN:UNKNOWN TON:UNKNOWN ESN:UNKNOWN
---- ISDN PRA CALL...
I have a PRI E1 link with slips that don't cause it to go down, they are kind of "normal" as it has been like that for some years. It is the backup link and it handles mostly incoming calls, but now I want it to be the main link. Would an increase in the number of calls increase the slips and...
I want to do a local Loopback test on a PRI2 , is it enough to interconnect the Tx BNC connnector to the Rx? or is it necessary to set it in loopback mode at LD 96? I know it won't go up since it can't be user/net at the same time. What result should I expect as succesful?
I have a Dual PRI DDP2 card with 2 links and I want to restart the one at port 1.
Their ADAN is GRP 3 DNUM 4 PORT 0 & PORT 1
I want to know if the following commands will disable just one link or both:
LD 96
DIS DCH 127
DIS MSDL 4
GROUP 3 <<< THIS IS A PROMPT BY THE NORTEL
LD 60
DISL 127
LD...
I'm trying to set up a new PRI link between my CS1000M v5.5, I created the DCH,Loop, route, etc.
the problem comes at enabling the DCH, it floods the terminal qith an error and it crashes the other PRI in the same Dual PRI card, until I disable the new DCH.I am not an expert at PRI DCH creation...
Hello everyone,
I have modified and reused a couple of PRI links in my CS1000M v5.5, but I now have to make a new one almost from scratch. I have a working PRI link in a dual Pri card and I want to use the other side (never been used).
I'm following Mike´s Cookbook, but at step 1 (I'm familiar...
¿Is it feasible to take out the HDD from a NTDW59BAE6 card and make disk image (ghost,etc.)? As an exact backup to avoid the exhausting proccess of reinstalling the CS1000e.
I'm trying to change a link OP11-op61 from SL1 to EURO, with a pair of NTAK79 PRI 2Mbps cards. on the op61 y goes well, but at the op11 when I try to rebuild (it doesn´t allow CHG) the dchannel with IFC=EURO it says the CTYP has to be MSDL and not DCHI. As far as I know it doesnt have MSDL, even...
I have seen in this forum what a TYPE SFP DN is and how to change it. I want to change SPRE=7999 to something else because I need a cdp=79.
besides changeing it in LD15, what other implications would it have? do I have to change anything else elsewhere? could I cause a mess?
EQUIPMENT: OP11 with old software.
EVENTS: Working normally, lightnig storm, happiness ended. all cards disabled (red leds)
When trying to connect tru the RS232 (I use it all the time) it responds with garbled text, I know the CPU is working because when I enter commands in the middle of the...
I have an oooold Op11 in tandem with a CS1kM 5.5 tru a PRI link (no carrier it's in campus) A few days ago exactly every other call from any set (digital & analog) it connects with only noise (voice unintelligible very low in the background). LCNT= zero errors on either side.
I tried taking the...
I have a faulty 2MB PRI card, I dont have the number at hand, it's the one with the DCHI & CC daughtercards. I have a NTAK10DC, can I replace the faulty one with it? does it need a separate DCHI controller card?. I think it has the CC built in.
CS1000E with 3 cabinets
Thanks.
Is Avaya still manufacturing new 3900 series telephones? their EoS announcements are confusing.
A project wich was delayed a couple of years is coming with a CS1000E a some 3904's, are they still NEW on sale?
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.