Hi,
I'm getting error perhaps you know what's the story is:
ERR054 27/11/08 09:20:44 446516
OPRDATA: 0 0 1
that was discussed already in thread798-1424960
but i don't have PECL set to YES on the route
and NAS was never configured (thread798-1425921).
thanks...
..Replacing a complete backplane solved the problem.
for sure it must be done as doing a test bkpl in ld 39 it is showing fail on link 21 but we don't want to shuffle with hardware and change part by part so if anyone had this problem before I appreciate just short infortmation what it was to...
to be honest it was always in place but issue was intermittend so hard to investigate. before office was quite empty. now when we have a lot of people in it looks like it is growing but of course becasue more calls.
after 20 test calls placed betweend Groups 0-1 or 1-0 silence (1way speech) or scratches for 2 calls.
Fiji Cards checked. no difference if it's on cpu 0 or 1. PS cards exchanged.
firstly thought issue in G0S1 as we had issue there with conf/tds card in specified slot. whole shelf was switched...
Hi,
Hopefully you can help or give me some clue.
In one site we have plenty of M2616 and only one M3904 created by my colleague. All "phones" are able to call each other except M3904 which has to call using whole number. from first point of view it seems that profiles are cofigured "the same"...