Yes offcourse... this is high time to change your old MD-110.
No matter it gives you good service but, it is an out dated model and you wont be getting any updares or valid support for this version.
Hope u understand that
regards
another way is to put another equipment in parallel and then put you can put priorities on both that if one is down for a while the other gets active, in normal cases one remains standby... or you can make it active as well at the same time so the data will flow to both the devices in...
I dont think there are loads of problems, if the parameters are alright VoIP works fine.
And also if you are planning to use CISCO, you can go for ISDN interface on CISCO and connect it to TLU76 MD, and rout it to your WAN network, you even dont need to upgrade to BC11 just for IP connectivity...
I think you guys have the same problem as we had.
Probably u need to approach Ericsson guys near you, this usually happens with induction in the OSP and high traffic rate, the solution is a firmware change on ELU29's.
Are you sure that the your Equipment is propoerly grounded and OSP is not...
size for FICRI as 60MB is ok for a system having approx 20 LIMs but it entirely depends on your system data. If the REL vol. starts getting FULL you get an alarm
Hi
U have to activate the ODN2 feature in Key function, and program the boss telephone in a key as MDN as CALT=1.
U can have two calls on both the access keys, and again if u see the Boss tel. blinking/ringing end one call and attend to it
ring time means the time before the B-party picks up the phone. yes it varies offcourse. Normally the charging starts when the B-answer is received,
the TIME parameter defined in CLODIis the one which is effective after B-answer or the call has been answered by B-party, and the duration is less...
hi
1.Can youo check the external as well as the internal Sync by SCEXP and SCICP
2. Can you send the prinout of GJLSP:Print=ALL;
do this print commands twice
3. Is the display on GCU2 changes between E5 and E6
and also did you check the records eneterd in CLINP.
Meaning that there is possibilty of omitting time in sec.By default it counts for all th sec, but you can set the TIME parameter in CLODI that the calls less this duration are not logged. this is done due to the reasons that usually 01 sec...