  1. ulhaq

    MD110 BC6 - 12 years old...

    Yes offcourse... this is high time to change your old MD-110. No matter it gives you good service but, it is an out dated model and you wont be getting any updares or valid support for this version. Hope u understand that regards
  2. ulhaq

    MD110 BC6 - 12 years old...

    What do u want to ask ... be clear
  3. ulhaq

    Call Accounting Dump

    another way is to put another equipment in parallel and then put you can put priorities on both that if one is down for a while the other gets active, in normal cases one remains standby... or you can make it active as well at the same time so the data will flow to both the devices in...
  4. ulhaq

    We are considering moving from BC9

    I dont think there are loads of problems, if the parameters are alright VoIP works fine. And also if you are planning to use CISCO, you can go for ISDN interface on CISCO and connect it to TLU76 MD, and rout it to your WAN network, you even dont need to upgrade to BC11 just for IP connectivity...
  5. ulhaq

    SPONTANEOUS RINGING OF ANALOG EXTENSIONS

    I think you guys have the same problem as we had. Probably u need to approach Ericsson guys near you, this usually happens with induction in the OSP and high traffic rate, the solution is a firmware change on ELU29's. Are you sure that the your Equipment is propoerly grounded and OSP is not...
  6. ulhaq

    SPONTANEOUS RINGING OF ANALOG EXTENSIONS

    Hi what revison of ELU-29 cards u have is this an upgraded MD110 regards
  7. ulhaq

    Invalidation of REl

    size for FICRI as 60MB is ok for a system having approx 20 LIMs but it entirely depends on your system data. If the REL vol. starts getting FULL you get an alarm
  8. ulhaq

    HOW DO I KNOW HOW ROUT IS FOR ONE BOARD?

    could exactly get the base question ??????
  9. ulhaq

    Can a secretary answer another ODN2 line?

    Hi U have to activate the ODN2 feature in Key function, and program the boss telephone in a key as MDN as CALT=1. U can have two calls on both the access keys, and again if u see the Boss tel. blinking/ringing end one call and attend to it
  10. ulhaq

    SMDR and call duration

    ring time means the time before the B-party picks up the phone. yes it varies offcourse. Normally the charging starts when the B-answer is received, the TIME parameter defined in CLODIis the one which is effective after B-answer or the call has been answered by B-party, and the duration is less...
  11. ulhaq

    Alarm E5 and E6

    hi 1.Can youo check the external as well as the internal Sync by SCEXP and SCICP 2. Can you send the prinout of GJLSP:Print=ALL; do this print commands twice 3. Is the display on GCU2 changes between E5 and E6
  12. ulhaq

    SMDR and call duration

    and also did you check the records eneterd in CLINP. Meaning that there is possibilty of omitting time in sec.By default it counts for all th sec, but you can set the TIME parameter in CLODI that the calls less this duration are not logged. this is done due to the reasons that usually 01 sec...