are you intercoming the extension? I believe a digital phone can not pass DTMF tones to an Analog Set when you are in intercom mode.
I haven't had issues with passing DTMF tones through GASM or ASM8+.
NTL555
Cheers to that. I love no longer looking in the manual for dip switch settings.
I never put in a FEM module as well in a 450, but I guess I will have to try once my FEM comes in. Thanks for all the help!
NTL555
Thanks for the response...
I called it the old legacy stuff because the BCM 450 uses slot instead of buses. The old BCM 400 4.0 would use bus number 2 thru 7. If you wanted to use Bus 2 you would set switch 1 on the FEM module on and the rest off and if you wanted to use Bus 3 you would set...
I read that as well in the installation manual.
My question is that if you max out all the bays with the FEM installed in the BCM 450 (10 bays used).. does that mean you have an additional 6 legacy modules available for use.
NTL555
I know the FEM module on the BCM 400 required a DS-30 bus for every dip switch set to the on position, but the BCM 450 is different. The manual says to have all switches on and configure it in the manager and the limitation is 300 sets, but my question is about capacity on that FEM and the BCM...
Another Update.
I had 5 more of the ASM8+ in stock and each had to be inserted HOT for the system to even start the firmware download and to be recognized by the system.
I dont know, but hope this helps anyone.
NTL555
I think that number is for only download, but it will depend if you actually get 3Mb up and down and what actually goes across that. Each conversation takes up 64Kbps up and down but you will still need a router that can handle quality of service.
You can be watching Youtube and your...
To me, it works fine, just got to make sure you implement QOS, establish a VPN between all locations, and make sure your data bandwidth is good.
NTL555
Snowman, yes it did show "started firmware download." Funny thing is once I inserted the card live, the BCM started to download its firmware and within seconds the MBM came right up.
I did attempt to configure and then install the module on Friday, but it didn't work. I will try what you...
If you have a Call Center application, the customer will hear music on hold until the next agent is available to take thecall otherwise, if a caller is being transferred from the AA or a receptionist, the customer will hear ringing.
NTL555
F983, log in with your UserID and Password, then hit AA, then hit Grtg, hit Grtg again, and choose your greeting.
This is only the company greetings and not the custom routing prompts.
NTL555
Update. So I've tried everything I knew what to do and do not approve what I am about to tell you, but it worked.
I got frustrated and took out the module hot (which I personally hate doing), double checked my switches, and inserted the MBM while the system was powered up (which I do not...