That's exactly what we have and no static at the main site StanleySteamer. AT&T says the T1's are clean with no errors! I haven't changed out the power supply to that box...I'll give that a try next.
Thanks
Thanks FBS...actually the ground was knocked off and we put it back on. I have a brand new power supply sitting there I wonder if that would take care of the problem.
Thanks MossEng, Not sure what you mean by earthed correctly? Are you talking grounded? I've had our vendor in here and he can't seem to find the problem either. I have not swapped out the power supply here at the main site yet. That is the next step.
We are running a meridian option 11 with 2 sites have a meridian 1 mini-carrier. The problem we are having is phones at the remote sites are getting random static. Has anybody experienced this problem. We've replaced the cards and fiber at the main plant. So far still getting static. AT&T...
Well not sure what happened but I can see it is now SCN instead of SCR but when I call his number my phone number still shows up on her screen. Is there a way to have it not show up? Thanks again.
That is exactly it!! I'll get the lingo down asap!! That is excellent! I can't thank you enough and you have just made the VP very happy!! Thanks again riteeh!
Hi all, I'm new here so if this is in the wrong place just let me know. I'm also new to supporting an Option 11. Here's my question. I had a VP request that his Admin see that he is on his phone when his office door is closed. So I added his DN to key 04 on a 3904. Now he wants her to be...