Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations TouchToneTommy on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by Midnite1971

  1. Midnite1971

    SCPU Failure

    OK....thanks for all the advice guys!! Anyone maybe have an idea of how this happened or what may have caused it? I currently have the maint. vendor on their way out.
  2. Midnite1971

    SCPU Failure

    OK.....can I split them while it says syncing? What would be the process besides the command SPLIT and SHDW?
  3. Midnite1971

    SCPU Failure

    OK....it's been like that for almost an hour....should I start worrying? A sync only takes about 30 to 45 minutes correct?
  4. Midnite1971

    SCPU Failure

    It sure does.....but now when I just went in it shows them as syncing even though I never did anything...weird. cp 1 16 PASS -- ENBL SYNCING DISK STATE = REDUNDANT HEALTH = 24 VERSION = Jul 28 2005, 04:14:02 Side = 1, DRAM SIZE = 512 MBytes cp 0 16 PASS -- STDBY SYNCING DISK STATE =...
  5. Midnite1971

    SCPU Failure

    Cables have been swapped out for new and the links are active...any other ideas?
  6. Midnite1971

    SCPU Failure

    Hey People.... CS 1000, 4.5 Normally I switch cores every once in a while just as a precaution but now I'm getting a failure...any ideas? CCED000 .scpu OK . SRPT048 DR: Master asked to stop updates and flush file system. CCED763 LCS: Graceful Switchover. Call Processing Stopped at 07:22:36...
  7. Midnite1971

    CCM Outage

    CS1000 4.5 Could someone please explain exactly what happened through these logs? I know that the link to CCM went down...but why? Thanks TIM461 13:36 29/10/2008 CPU 1 % % AUD021 073520B2 00001002 00000003 00001908 00000000 00000000 00000013 00001908 % % AUD028 073520B2 00001002 00000003...
  8. Midnite1971

    RCO listing

    Thanks for your help!!!
  9. Midnite1971

    RCO listing

    Is there a way to print all phones that have a specific RCO? Thanks Tim
  10. Midnite1971

    Dch Error or Not?

    Thanks so much for your help.....it's appreciated. I have turned on dch messaging in and out for both of those PRIs....and we're an Outbound Call Center. Will so many messages being spit out affect the PBX in any way? Thanks
  11. Midnite1971

    Dch Error or Not?

    5ESS....set at NI2...here's the Dch programming. On one of the PRIs they had it setup with RCAP- COLP and NDS, I removed NDS and at least the fast busies went away. ADAN DCH 1 CTYP MSDL DNUM 14 PORT 3 DES PAETEC USR PRI DCHL 25 OTBF 32 PARM RS422 DTE DRAT 64KC CLOK...
  12. Midnite1971

    Dch Error or Not?

    OK....here's one with hex. Thanks!! DCH 1 UIPE_IMSG CC_SETUP_IND REF 00007F83 CH 25 7 TOD 10:45:23 CK DB249E77 PRIM HDR: 2F 00 03 00 5C 00 MSG HDR: 08 02 03 FF 2E 00 BCAP: 01 07 13 00 85 90 00 00 A2 CHID: 09 09 0D 00 A9 00 83 00 01 0CAD#: 03 0A 03 00 80 00 04 00 07 06 07 08 GFFAC: 37 1A 19...
  13. Midnite1971

    Dch Error or Not?

    It does except for those several setup messages...and they happen on every call out of that PRI. DCH 1 UIPE_IMSG CC_FAC_IND REF 00003C03 CH 25 4 TOD 9:39:31 CK DAAC01D1 DCH 1 UIPE_IMSG CC_FAC_IND REF 00003C83 CH 25 5 TOD 9:39:35 CK DAAC2934
  14. Midnite1971

    Dch Error or Not?

    I've turned on d-channel messaging and one of our PRIs keeps having an incoming CC_FAC_IND message. What does this mean? I understand the alert messages but not the facility messages and our other PRI does not do this. CS1000 4.5 Thanks DCH 1 UIPE_IMSG CC_SETUP_IND REF 00003C03 CH 25 4 TOD...
  15. Midnite1971

    Fast Busies on Outbound

    OK....I have one...what is a Cause: #31 DCH 5 UIPE_OMSG CC_SETUP_REQ REF 00005394 CH 13 17 TOD 14:28:32 CK 56D6F19D PROGRESS: ORIGINATING END IS NOT ISDN CALLING #:18884958645 NUM PLAN: E164 TON: NATL CALLED #:12124873702 NUM PLAN: E164 TON: NATL DCH 5 UIPE_IMSG CC_PROCEED_IND REF...

Part and Inventory Search