Hello!
Recently we had a "broken" Phone 30, which didn't communicate with the IPO. (blinking green light, then after DTE - solid red light and TFTP Poll timeouts)
Now i'm happy to announce that these modules can be repaired, the communication IC should be replaced by a person who is capable of...
Okay. But it works if the "Set Authorization Code" shortcode is not used: dialing 202123 will call this number, not the extension 202.
Even if i set the line group of the set auth short code to the ARS, it will just dial the extension immediately..
I'm looking forward to see a better solution...
Hello!
The situation:
IPO 500v2 with R7 (and R5). Users' calls must be logged and priced, users can set if a call is private or business call. Users must authorize themselves with 4 digit codes.
So two short codes are created: 0XXXX# and 8XXXX#, both TN: . and with action Set Authorization...
intrigrant,
So you say there is an option (solution) for ipo 500v2 system with 5410/5420 phones to visually indicate the user has a missed call? I searched, tried, but didn't find a solution so far, that's why i'm asking, not a monkey trick or something.
I know there is the call log menu, it...
New voicemail message get displayed. But what if the calling party finishes the call before the call could be forwarded to voicemail? Or voicemail is not on. And even if the user has new voicemail message, it must be checked to un-lit the message light, isn't it? So it makes hte process more...
Hello!
We are using IPO 500v2 with 6.0 (18) and 5410, 5420 phones. Is it possible to indicate if the user has a missed call? Missed calls are logged, but if the user does not check the missed calls log in the menu, he/she is not notified about the new missed call.. Any solution for this?
Thank...
Other modules, Phone30, another Phone16 is working on the 406v2, even same port, i tried the "faulty" Phone16 on every port of the 406v2, but same.. blinking green. However, it is working on the 500v2 :S
Maybe I didn't mention it, but the PHone16 was working for years with the 406v2, then it stopped working.
After attaching it to the 500v2, the Phone16 updated itself from the IPO, and started working, but back on 406v2 it just blinks green...
How should I set it for R5 if you are right?
Hello everyone!
We have an IPO406v2 (5.0), with Phone16v2 module. It suddenly stopped working, blinking green all the time, the IPO doesn't see it.
We have an IPO500v2 (6.0), which strangely can handle the Phone16v2 module, everything works fine with it.
How come the 406v2 can't use it? We...
Hello!
We changed our Bosch I3E to IP Office a few years ago. There are about 200 users on it, and we use PIN codes to authenticate users for each non-free calls. On IP Office, we use Authorization codes, with Force Authorization Code enabled. Created a ShortCode: 0XXX#;SetAuthorizationCode...