Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Chriss Miller on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by etompau

  1. etompau

    how to repair the screen of ERICSSON type dialog 3213

    There is no jumper on the PCB related to the display. As I said, just replace the display, that's all there is, as long as the phone is working of course.
  2. etompau

    how to repair the screen of ERICSSON type dialog 3213

    The Dialog 3000 series use a standard LC display, and it's just a matter of inserting an new module and the display should work.
  3. etompau

    DT590 firmware update fail - phone cannot restart

    A failed FW download should be possible to restore, by running the download process once again.
  4. etompau

    BP 250 BMS

    You need to enter the Full Standard Licence code in the BMS server in order to get full functionality.
  5. etompau

    BP Soft & firmware download site

    The only site I'm aware of is Aastras official InfoChannel. Certified re-sellers have access to this site.
  6. etompau

    BP250 power consumption Urgent question

    Have a look at the help files in BMS, you will find a lot of information and facts regarding power consumption. A BP250 with a CPU, ELU-A and an IPU board is no problem for the power supply unit.
  7. etompau

    what RYS / ROF /LYZ stands for

    The strange acronyms like RYS/TYT/ROFNB/BKBN is part of Ericsson's ABC-coding system. You need to have Ericsson (internal) document in order to decode these acronyms. From my memory: RYS=firmware often in a chip, ROF=Printed circuit board.
  8. etompau

    ISDN synchronization problem with Aastra BP 250

    Have a look at command 2061...There you specify synchronization of the system. You will find all information you need in the BMS online help system.
  9. etompau

    DBC 4187 on BP 250

    The CLIP function needs an certain minimum SW/FW level and hardware revision of the extension board. As far as I remember all MFU boards support CLIP.
  10. etompau

    All digital phones are not ringing in BP 250

    1. Restart the board. 2. Check the ring alternative for the extensions.
  11. etompau

    Ericsson BP250 Least Cost Routing

    The manual is included in the web based programming tool called BusinessPhone Management Suit, in short BMS. You need this tool in order to do your LCR programming. Ask an Aastra dealer, they might help you with a copy of this program.
  12. etompau

    Password access MD110

    Don't expect an answer to your question. Basically what you are asking for is a criminal action.
  13. etompau

    Where to download Ericksson BMS Software

    If you are a certified Aastra partner you can download the BMS from AAstra's InfoChannel/service Plaza, if not, you have to ask someone who is.
  14. etompau

    hi how config ip&gate keeper &user

    Default IP=130.100.17.100 You must start the phone in Admin mode and press the the lit DHCP key in order to use the default IP address.