  1. chooseU

    IP Office 406V2 - XO IP Flex PRI not coming up

    Thanks, everyone, for your help. Here's what ended up working: Checked CRC box. Un-checked CSU box. All other settings the same as above. D-channel came right up after these changes.
  2. chooseU

    IP Office 406V2 - XO IP Flex PRI not coming up

    Yes--we didn't get a signal on the straight-through. Will collect the traps and post. Delayed the number port, so we could get to the bottom of this.
  3. chooseU

    IP Office 406V2 - XO IP Flex PRI not coming up

    thread940-1571028 Looking for help from those that have implemented an XO IP Flex PRI with an IP406V2. Our customer's IP406V2 is currently connected to a Verizon PRI and works fine. However, each time we try to switch to their new XO IP Flex service, the D channel will not stay up. Have...
  4. chooseU

    Forward calls remotely from VMPro

    It's the Play Config Menu.
  5. chooseU

    Brooktrout TR1034 T1 configuration

    I haven't been able to try this in person, but the customer says the phone system "lights up like a Christmas tree" when he plugs in the T1 cable with the line set as KWING suggests. However, he installed a dual T1/PRI card in a 406V2 which already contained a dual T1/PRI card. Any thoughts?
  6. chooseU

    Brooktrout TR1034 T1 configuration

    No, it's an 8-port.
  7. chooseU

    Brooktrout TR1034 T1 configuration

    Forgot to mention: All inbound voice traffic is coming into a dual PRI card (they have 2 PRIs). The customer added a second dual PRI card to the system, not knowing that only one of the ports would be supported on a 406V2. One of the T1 ports on the new card is connected directly to the...
  8. chooseU

    Brooktrout TR1034 T1 configuration

    We are attempting to set up DID faxing between the IP Office (406V2 - 3.1.65) and a RightFAX server with a Brooktrout TR1034 installed. The Brooktrout board is showing a green light, but we can't pass any traffic either way. I've set up short codes based on other information found on this list...