On newer 200 rel 3 and later make sure that in the pri trunk descriptor QSIG Supplementary Services are are disabled it is on by default. with this enabled you will not be able to forward.
If 7.1 there is an issue with how memory is accessed in this release. You can either upgrade to the latest 7.1 with SP or go to release 8 the issue is resolved.
I have networked dozens of SX2000 and 3300 systems. Although it is easier to have a uniform dialing plan it is definitely not required. Opsman will ensure the dialing plan works. Keep your cluster element ID's the same length as the extensions. Keeping the numbers unique only allows you to...
make sure you have a copy of your imat db or you know your settings as the below steps format the card for the new release
Get the 8.x release from MOL and extract the files that are in the zip to a folder on your C drive such as temp
you will see a folder called PRI_INSTALL
open that folder...