thread798-1611602
We are having problems with a new CS1000E system at release 6.0. Two MGU cards have gone bad in less than 3 months. All FAN LED's are flashing red and green. Does anyone know of a know problem for these. I have referenced a thread from July 2010 from another user but there...
We have corruption on three TN's at the moment. ACD agents / Supervisor were moved using MOV, ECH etc... I know it is not the way to do it but the tech was not aware.
The TN's in question show that they have a supervisor. Cannot remove the agent or delete the TN. Problem is the key they...
Call Pilot 1005r Release 5.0 SU 8
If I access our Call Pilot through a PRI from another switch on campus (direct fibre), it does not let me log in to my mailbox. Seems like it does not recognise the DTMF tones. I enter the mailbox number then #. It asks me for a password which I enter and then...
I have a card option (3 cards) that has an issue after a power failure. Question I have is:
Can I replace this setup with a single card Meridian mail ?
Thanks
I am at release 5.0 and am looking at this exact problem. Didi you use biv343's suggestion? I have done the dosFsShow /d command but want to be sure before I attempt the cbioRdyChgdSet command. Has anyone done this successfully on a 5.0 system?
Thanks.
If biv343 is available, can you...
thread798-1592416
CS1000 MG Release 5.0 / TM 4.0
When acessing the troubleshooting tab for a particular set, I get the TBUG632 message instead of IDLE or BUSY.
Noticed that it does not do it for older systems 25.40B or on a particular release 5.0 system without a DEP list installed.
Any...
Your statement:
OK--Since Verizon said we were sending CallerID I went ahead with our contractor and set HLCL to 254-3729 and ESA_apdn to yes. I then called a number and did the TRAC. It is showing our calling number to be 202-254-3729. I can only assume from this that Verizon is sending the...
Just to update: The problem was really narrowed down when the power supply smoked in the switch. (11C) I was surprised since SYS809 did not seem to point to power.
Thanks for the replies
Good morning,
Running an Option 11C at Rls 25.40B
The unit performed a SYSLOAD and I am trying to determine the cause. Have not seen 000809 in posts before.
The switch also did not come up clean as I had to get two TMDI cards hard reset in order to be able to send enable commands to them...