  1. burnyourmoney

    Can't assign access codes to Line PoolC

    Found the problem. There were 7 ext in the 700 range. I renamed them and all is well. Thank you everyone!
  2. burnyourmoney

    Can't assign access codes to Line PoolC

    Company A is using line pool A (Access Code 9) and also line pool B (Access Code 8). I am trying to set up company B with line pool C (access code 7) but I'm not able to. I can't input any number for that matter. I checked the routes and they are all "no numbr". Dest Codes are "none defined"...