Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Wanet Telecoms Ltd on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by bolsonttu

  1. bolsonttu

    Merlin Messaging RS-232 Connection

    Hello All- Our network recently was rebuilt and the Merlin Messaging IP Address is now no longer on the subnet of the new network. I am attempting to access the administration interface through a serial connection. I have found documentation that requires a 355AF adapter, DB25 to DB9 adapter...
  2. bolsonttu

    Merlin Unified Messaging 4.0 Problems

    Thanks for your responses! I think I need to do less whining and make my questions a little more clear. I guess the bottom line question is this: Is it possible to set up the SMTP component to send mail to an SMTP server that requires a username and password to be verified before sending any...
  3. bolsonttu

    Merlin Unified Messaging 4.0 Problems

    Hello all- I am having some serious problems getting UM up and running. We currently run Exchnage 2003 through a hosting provider, so using Exchange integration is obviously a no-go. However, I tried getting the SMTP option working, still a no-go. It seems that our Exchange host performs a...
  4. bolsonttu

    Only the message light is blinking on 4412D+

    OK ... Just to update everyone as to my status. I removed the board, rebooted the system, did a board renumber, added back the board, rebooted again, didanother system renumber, and VOILA!!! My new board is back. I was able to program the new extensions without any problems whatsoever. It...
  5. bolsonttu

    Only the message light is blinking on 4412D+

    Here is the output from the slot status: LED: Ron Yoff Goff Errors: no Mode: Standby Alarms: no Maintenance Busy: no I am thinking that Ron means that the red light is on, and there is an error on the card, but why does Errors: no show up?
  6. bolsonttu

    Only the message light is blinking on 4412D+

    Well, no one is on phone connected to this slot. I get a RESET SLOT FAILED message. You know this is pretty weird, considering this was a brand new module still sealed in original Avaya packaging. It seemed to be working correctly when I began programming the station port. What to do??
  7. bolsonttu

    Only the message light is blinking on 4412D+

    I have tried resetting the slot (#7), and busying out the slot, and both attempts give me a FAILED message. Do I need to make sure that the system is not in use before I attempt this?
  8. bolsonttu

    Only the message light is blinking on 4412D+

    Yes, I renumbered the block of extensions on the board to become 3-digit extensions in sequence with the existing system. If I go through SPM Maintenance -> Slot-> Reset What will happen? Will the system need to reboot afterward? Will it take it to factory defaults?
  9. bolsonttu

    Only the message light is blinking on 4412D+

    Thanks for the reply Pepperz. The wiring checks OK. I have switched sets with a known 'good' phone, and still nothing. It also seems as though every port on the card has the same result when a phone is plugged into it. I was programming this phone after an install of a new 024TDL module. I...
  10. bolsonttu

    Only the message light is blinking on 4412D+

    Hello everyone! I was in the middle of programming a 4412D+ connected to an 024TDL module using SocketSPM when SocketSPM "Blew Up". Now the only thing that will light up on the phone is the Message Light and it is blinking. No dial tone, no info on display, everything is dead. I have tried...
  11. bolsonttu

    Adding 024TDL Module to existing system

    Thanks for the reply Tom. I did the board renumber, however, all of the extensions on the new card are four digit extensions 7156-7179. When the system was originally set up, it was programmed to have 3 digit extensions. Do I need to do the Set Up Space function? Thanks Again, B
  12. bolsonttu

    Adding 024TDL Module to existing system

    Hello again everyone! I have finally got around to installing this card in the system. It is in Slot 7...the last card, just like ya'll suggested. Now where do i go in the SPM to do a board renumber? I have found the system renumber, but bard renum. Thanks for all of your advice! Brandon
  13. bolsonttu

    Adding 024TDL Module to existing system

    Hello all! I have an existing Merlin Magix system configuyration as follows: Processor Cabinet Processor 4.0 412TDL 016ETR 016ETR Merlin Messaging 4.0 800 GS/LS-ID Expansion Cabinet 800 GS/LS-ID I am adding an 024TDL module to the system. Just from reading the other posts in this...
  14. bolsonttu

    HOW-To: convert voicemail message to audio file

    Sorry, Here is the reference for the thread in mentioned in the above post: http://www.tek-tips.com/viewthread.cfm?qid=1038649&page=7
  15. bolsonttu

    HOW-To: convert voicemail message to audio file

    Thanks for your post Tom! I am currently running Merlin Messaging 4.0.42. I tried backing up the VM system. It seems to me that all configuration info and VM messages are saved in a proprietary format and not as separate files. If anyone else knows any different ... What about using Unified...