we want to connect my home to work using a wifi connection but dont understand the technology at our disposal,
work has two (bt up to 20mb (6.5) adsl connections), the servers that i need to access (sad workaholic that i am), on a full 1ghz lan, with our voip connection
home has std bt rural...
thank chaps
we went on as discussed, we used server 2008 as the host as it was hosting, pdc and ms exchange so it would be easier to dcpromo down, backup exchange and to transfer the roles onto the appropriate vm servers, we then set up four servers
1/ pdc, 2008 r2 ent running pdc dns, dhcp...
dont want to be a pain but :
we have:
a 2950 (server 1) 2x quad 2.3Ghz 6x 750Gb raid5 and split into 2 partitions c: 2.0 Tb d: 1.5 Tb, this is fine had hdd fail other day swapped for new one all worked fine. this server now only runs dns, dhcp, exchange, and pdc roles
1x hp dl380 (server 2)...
hi doktor the switches are:
sw1 is in the on position
sw2 123 are on 4 is off
tis is the same as on the previous system, this morning it was cycling every ten mins so i have removed all not in current use ie adsl voib and serial board seems to be holding now if this carries on i will...
can anyone tell me where i can find the 3.7 firmware upgrade for a nexer ipldk-24 3.0Eb (advice on doing it would help, though i ass/u/me it is a staightforward operation to carry out)
i promise that i have looked through the forum but cant find it
regards adrian dunbar
i have a nexer ldk-24 that randomly resets itself, sometimes locks up and needs to be unplugged to reset it then works fine any ideas system is:
ldk 24 ver 3.0Eb FEB/06
BFBE2
DSIB8
DTIB8
WTIBE (REV 1.4 SW1 OFF SW2 ON SW3 ON SW4 OFF)CLCOB4
BRIB2 ALL SWITCES (4) ON
VMIBE2 VER1.4
VOIU8...
HI DOKTOR
sorry been real busy, had a leak in the roof lost my nexer, which i have now replaced by way of ebay for an even better one, my new system comprises of:
ldk 24 ver 3.0Eb FEB/06
BFBE2
DSIB8
DTIB8
WTIBE (REV 1.4 SW1 OFF SW2 ON SW3 ON SW4 OFF)
CLCOB4
BRIB2 ALL SWITCES (4) ON...
hi doktor have been busy but i have almost sorted it but am having problems with updating changes , can you tell me is therer a routine for this, i have tried both reset and initialize with the dire consequences that follow how do i do it properly one of the main problems is that on the fax line...
hi chap you can download 32 bit version from microsoft and use your licence key but youll have the usual probs with it not liking any other ms product i think weve all been here before
thanks that makes so much sense,
so now if i put line 8 (fax) into co group 2 i can isolate the fax printer from all the other incoming calls by using co access pgm117 ?
thank you for your time if i get stuck ill come back
regards adrian
help im trying to get my LGE/UK24P-3.0Cb NOV/05
Nation : U.K. (v3 nexer)to default to line 1 on dial9 at present it goes to line 8, also interested in any other help available system has:
CBFB
DSIB8
DSIB8
WTIB (3XWTB100)
BRIB2 (LINES 1+2 ONLY USED 3+4 FOR EXPANSION)
LCOB4 (LINES 1+4 ONLY...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.