THANKS leedsit and PederChr
I have a checkpoint in windows 2000 with two alteon 5114 nortel in cluster mode. I had to change one alteon so i installed the linux in the new alteon and i used the join command to put both in cluster again.
I see the configuration is ok (ports and interfaces)...
hello,
I have two alteon 5114 nortel in cluster mode with a Pc with CheckPoint. One of them lost the System Operating. I have reinstalled the linux but now I need to configure it. The join command will let the alteon in the same way it was before??
Thanks!
OK,
My co-workers dont want configure STP only for the change of topology and dont want to probe the EAPOL but... i think it is necesary for our network.
repaRU I WANT TO THANK U FOR UR OK ANSWER!!!!!!!!!.
Hi all,
several questions
Can i configure eapol in Passport 8100?? (I think no)
Can i integrate with ACtive Directory?
Will be good for a network with about 1700 users?
Thanks!!
If i configure STP then i avoid loops but i have the problem of change topology, else someone can create me a loop in my network
Then, configure the STP or no? What do u think?
Thanks again!
sorry me, my english is not good.
STP work: In network with STP enable there are a root. This root is the fastest way to send a packet. When i insert a new element of the network, perhaps occurs a change of topology's(the system look for new "root" ). During this process the network is down...
Hi !
OK i understand,
but how can affect to the efficiency of the network in the users to enable the stp, when the network try to look for root when change the topology.
thanks
Thanks repaRU!!
I probed the first case and it is ok.
I dont understand the configuration of second case (loops between 8600 and 8100 for example). Please correct me:
Configuration 8600's:
STP globally disable
create STP1 and STP2
STP1 add (smlt and ist port)
STP2 add (mlt ports and...
I have just found:
Message System activity performed
Severity Info
Description This message is generated when the system clock is synchronized
with real-time clock (RTC).
Synopsis N/A
Action No action is required.
document...
Hi!
It is interesting u tell and i think as your, i connect everyday (only to see the logs), i dont save the configuration all days but everyday the logs tell me the same:
connect from...
This message repeat 86 times.
System performed activity
What do u think?
Thanks for ur reply
Hello!
I have two passport 8600 with IST, several 8100 and 470 with SMLT to 8600.
My question is:
How can i detect loops in 8100?.
The clearloopdetect down the fiber ports and isolate the 8100 but dont find me the two ports who create the loops
Thanks!
Hello:
Actually i don't have an alarm when a port link is up or down, i only recieve a trap but with the number interface not with the slot/port so i cant filter...
Thanks
Hello:
I have a stack of bst 470. When i connect by telnet or console and i start to write the password the bst clear me the characters, only i can entry when i write the password suficiently quick (copy-paste). I have no problems with DM, and it occurs me in several pc's (hyperterminal...
Hello:
I'm trying to filter in fault view (ONMS 10.1.3) when a slot/port (or interface number) link is up or down. I put:
192.168.1.100
and
Slot/Port = S1P1
but dont work well, can someone help me ?
Thanks!