Thanks for that, I know that the service provider has provided 30 channels, I just thought that since I have the 8 default then I can use them or rather get them in service as I still get the additional 22...if only to test whether the E1 is up. Is that possible or will I have to wait until the...
I am a business partner and this is not my 1st E1 install, but it is my first on IP office, I have worked with CM before and never had such issues.
Thanks
Hi RTGDFM,
No I am not in the UK, I am in Kenya. I would also like to know if I should be using E1R2 or PRI30, Currently I am using PRI30. The LED is green but it keeps flickering to orange after sometime and that is why I think it's just something small.
Here is a full list of my parameters...
If my cable had issues would the line be able to work with a trend tester? I am just asking. So I am just thinking that the cable termination is fine. The SP is also set up for master.
Thanks
Hi,
Yeah I am using a PRI cross. My question really, is whether there is anything special that would need to be set up to get this thing up and running. I feel that it is just something small, some small parameter I am missing. How I would wish to go to system status and see in service and...
Hi guys,
I need some help on how to get my E1 to be in service. Currently on system status it shows out of service. The service provider has visited the site and using a trend tester has confirmed that the E1 is up on their end.
My E1 is set up as follows:
Line subtype: ETSI
Line signalling...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.