  1. necom

    Cisco WAN config troubles.

    Update: Finally, today its working. It was the telcos problem (SBC).
  2. necom

    Cisco WAN config troubles.

    Hi jeter, I'm using a straight through cable (standard patchcord pinout). Are you saying that if I put a loopback plug in the NIU on one end, the other end should show loop? I ask because I tried that to see if it would bring up the router on the other side in a loopback state, it did not.
  3. necom

    T1 vs. t1, S0 vs. Controller t1???

    When configuring linecoding and so fourth on my Serial interface, I can choose either t1 or T1. Whats the difference? Also, instead of putting linecode commands on on the serial interface, I see it put on the "controller t1" in examples online, is this better practice, or whats the difference?
  4. necom

    Cisco WAN config troubles.

    I'm not sure if there is any other interference. I'll be out there tomorrow with 1 new router and the two originals to test. I'll connect directly to the smartjack with a short cable and see what happens.
  5. necom

    Cisco WAN config troubles.

    Yes.
  6. necom

    Cisco WAN config troubles.

    They've already tested it, they say their stuff is good.
  7. necom

    Cisco WAN config troubles.

    Internal csu, configured for full. Would CSU/DSU settings in the router cause it to flap like this? The only settings I've done for the serial interface is IP address/mask so shut service-module t1 timeslots 1-24 b8zs, esf (confirmed through telco) bandwidth 1544 clock source internal (line on...
  8. necom

    Cisco WAN config troubles.

    I'm using a straight through cable (although it is pretty long, maybe 250-300 feet), on the clock question, I tried it with one side using line and the other using internal. No luck either way.
  9. necom

    Cisco WAN config troubles.

    I have a point to point setup and 2 Cisco 1720's (one at each end), for some reason when I connect the routers to the smartjack, the light go green and look good, but it keeps changing from LINK up to down and then up again about every 30 seconds (flapping). Everything is at default, this looks...