Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations wOOdy-Soft on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: MirkoGradassi
  • Content: Threads
  • Order by date
  1. MirkoGradassi

    DIFFERENCES BETWEEN TLU64/1 AND TLU76/1

    What are the main differences of this 2 tipe of boards= TLU64/1 and TLU76/1? In past, i did connect my BC9 system with asterisk machine via tlu76/1 and pri EuroISDN. Now, a customer with passive TLU64/1 board want to use it to connect with an asterisk machine, does it work exactly like a tlu76...
  2. MirkoGradassi

    Modem camble scheme

    I need to find the scheme of the cable that connect the ipu and an external modem. I've something like this: MD -----> DB25 A1 3 A2+B2+C2 7 A3 15 A4 8 B1 2 B3 20 B4 4 C1 17 C3 6 C4 5 but it don't work. help me please...
  3. MirkoGradassi

    Q.Sig over TLU 76

    Hi all, I'm trying to interconnect a BP 250 with a Md100 via TLU 79. Everything is working fine if I configure the machine with standard ISDN protocol. When I try to change the protocol and use Q.sig nothing work. I cannot call from Md110 , my extension report "category not allowed" and...
  4. MirkoGradassi

    Remove Magazine in BC9 System

    I need to remove a magazine froma BC9 System with 2 magazines. I've shut down everything, than Disconnnect the DSU and power from second magazine. I've cnboe all of the board in mag 1 and temove the reu. Then I've switch on magazine one, block the lim with the command BLLTI:LIM=1; and refresh...
  5. MirkoGradassi

    Conference code with digital phone

    Is it possible to start A conference using the code "3" with a digital phone system in BC9? I'had try but nothing happne, I can only start conference by programming a key but with the analogue telefhone che code "3" work fine. Any ideas? Bye Mirko
  6. MirkoGradassi

    Operator Password in BC9 System

    Is it possible to configure a passoword for operator consolle in order to make night/day switching controlled by password? I've not find anything about this possibility. Thanks Bye
  7. MirkoGradassi

    Moving ICU and Voicemail

    Hi all, I need to move a voicemail server and the ICU where it's connected from LIM 1 to LIM 3. I've Transfer about everithing but the ICU. I have no idea How move the ILP unit from lim 1 to lim 3 in order to get the ICU work. The progra I use is Provoice. I've try with CNPIP:UNIT=ILP; for...
  8. MirkoGradassi

    What does it do?

    I've a special extension number programmed on a Key of a digital phone. When the user click on the key, he would the a own line but nothing happen, the code associated with the special number is a mistery for me, con someone help me? Here the configuration: SPEXP:DIR=ALL; SPECIAL PURPOSE...
  9. MirkoGradassi

    ALU-2 Alarm Input Part

    Hi all, I've an ALU-2 board and I need to create an alarm only when the voltage on AL goes down. I'm capable to open an alarm when I receive the 48V on my input port, I had done it with the command: ALEII:BPOS=1-1-20,ALI=1,CODE=801,TEXT=ALLARME1; But What I need is exactly the opposite...
  10. MirkoGradassi

    Fictive Numbers?

    Does exsist fictive number in Md110 BC9 System? And if yes, I've found nothing about it in documntation, what I've to searching for? I need to inizialize a fictive number and then I will program the suprvision of fictive on the keys of 2 digital phone so they will ring together. Bye Mirko
  11. MirkoGradassi

    Too short times for answer

    Hi all, I've a problem with an MD110 connected via Q.Sig with a BP 250. The call arrive on MD and then are redirected to the BP via q.sig. I've notice that the phones ring only for 4 rings then the caller get disconnect. I would change this times in order to make phones ring for a long period...
  12. MirkoGradassi

    Help on BoardID

    Who know what board has id 59? Better.... Where I can find a list of boards with the corrispondent Boardid? I'had search it in dynatext but I had find nothing. Bye Mirko
  13. MirkoGradassi

    Presentation and quesion...

    Hi to All, I'm Mirko an italian tecnician, I'm a totaly newbye with the MD110 system and now i'm studying it, here I am to ask you some help :D I've a problem with the MD110 that I use for tests, it report an class 4 alarm says: ********************** DATE: 12JUN05 TIME: 10:30:36 CLASS: 4...

Part and Inventory Search

Back
Top