Hi,
MX1,
got 4 422 phones, 3 phones have MNS keys set up for 4th one.
eg.
26067 / 26068 / 26069
monitored phone is 26060.
when ringing 26060, MNS lights do not come on
SUDIP shows MNS keys set up as does IIS server.
IPURI, force =yes, also factory reset phones, to no avail
tried to kill...
Hey,
(MK-1)
I have a generic user who is MNS'd onto another generic user (switchboard) IP phones
SUDIP: shows
DIR Keyy
*4000
2900 40 0
KSMDE command
KSMDE:DIR=2900,MNS=4000;
returns DIR not an ODN
help !
HI,
We have an MX1, which gradually has had more IPLU cards fitted,
We are starting to get various issues, congestion, pretty much all the cards are showing 364 minor IP alarms.
(4 LIM system)
Customer data-networks etc etc have all been checked as ok.
Have been told needs going to service...
I have an IP phone with a generic number,
i need to change the number,,
1> AUCOP ok
2> PELPE
3> GEDIE, says terminal assigned
under SUDIP
dir= xxxx
equip pos =x-x-x-x
ip add =x.x.x.x
can I just change the DIR ? or I need to end this, does the user need to log off the terminal phone ?
Is there a known fault with rouge faults on sites which have been upgraded to BC12.. reporting 102 alarms as blips, for all mags (DSU) and showing inf2 as 4 (Ringer)
cards have been changed as have PSU's REU and PU5dc, also assorted line cards
thankxs
1> Is the extn’s IP address identifiable from the MD110?
2> How are the extns assigned an IP address? Is it done dynamically by the Gatekeeper or is this manually entered on the MD110?
3> In the event of WAN failure, do the phones automatically register to the EBN?
4> What measures are in...
Hi All,
The fault is for all 4 DSU’s ADDINFO2 = 4.
But its intermittant, comes in for a second and then goes, every day or so.
cables all checked and ok
As a comparison:
LIM 1 MAG 0
Power card PU5DC /1 R2B
+5 5.1
+12 11.93
-5 4.97
LSU /5 R2A
DSU /4 R7B
LIM 3 MAG 0
Power Card PU5DC /1 R2B...
hi,
after a reload in a switch (bc12)
the digits for call duration has gone from 5 digits to 4 digits,,, (RAW data output)
when compared to another switch CLFOP, is the same and in CLINP form is set to 4
any ideas
thankxs
peeps,
having a problem killing off a card,
Allop shows
cla 4 269
only one channel on syedp
1-0-40-00 48
ROEQE wont work, ( no ROU or TRU figure)
CNBOE wont work (individual still initiated)
tried RFBOI as well, before doing above
need to kill the alarm, obvisuly not properly uninstalled...
have a BC12 site,
with "LOADS" of the below events logged, on 4 out of 6 LIMS, events show 100 with over 800 overwritten,,
all LIM's have same error.
Jump to Illegal state ALEX says needs a patch
thankxs
< HIMDP:LIM=4;
DIAGNOSTICS FROM OPERATING SYSTEM
TIME DATE ERROR CODE...
Hi,
I have a problem with what I believe is number corruption.
Previous fault was an ana, ext. which when dialled DDI, would not work, gave VACANT number, I prooved it was the number and not the extension, by killing the extension assigning a new equ to it and the old equ to a new number and...
Hi all,
I am getting a lot of 278 alarms(CIL DATA LOST FOR ONE OR MORE OUTPUT UNITS) in all LIMS
GJLSP print shows all PCM links with errors
(BIT 6 - incomplete clock ordering in Group Switch)
Did SCICI and SCEXI
also did
GSRFI:GSM=0,GSSIDE=0
Alarms still on Links, also problems with...
Hi all
MD110
BC10 CNA144
No ouput of alarms...
I have
1> checked Alapi command
2> restarted NIU card
3> also ALH1, ALM and ALR,
I can test only remotly, but if I log on to the alarm port and stay logged on while I generate an alarm I dont get a "unable to sieze i/o port" alarm
anyone ?
cheers
BC12 site,
International dialling, gets "barred" when dialling 900
changed cat to known international cat get same thing
SO, got it working by deleteing extension and bringing it back in, theh changing cat back and forth, all works
I have several extensions which I think have same problem...
can anyone confirm that
keeping DNA operators in "BUSY ABSENT" mode, by locking it up will cause problems with software
either lock up's on other consoles, or one way tx or other weird gremlins
thankxs
PM