  1. chrisay59

    MG1010 - MGU

    Hi Guys, I was wondering if anyone else out there has had an issue with the MGU on MG1010 blowing componants, namely C12, C13 and/or L1 on the PCB. I have had three in the last 7 days!
  2. chrisay59

    The longest open case in Nortel

    This is the response I got from Nortel when I asked for an update to a Business Critical Case I opened 8 weeks ago. ............................................................ MPLR29758 causing HIGH Call Reg Usage'. This problem is over 19 years old. It was first reported in...
  3. chrisay59

    Fax issues with Rls 6 and SIP DDI Trunks

    Hi guys I am having an issue in regards to incoming external Faxes via SIP Trunks, basically it appears that G711 pass through does not work, the CS1K keeps trying to re-negotiate it as T38, and the Fax fails. Not surprisingly our provider has just told us that they do not fully support T.38...
  4. chrisay59

    UM and Geomant MWI to CS1K Integration

    Guys, we are currently trying to integrate our CS1K into UM using Geomant to provide MWI on our phones, however we are having no end of issues, but one of the things that has come about since the start of the integration is that we are getting the following error on the CS1K ERR4080 FAIL Q+P...
  5. chrisay59

    ERR SRPT4653

    Hi guys, has anyone experienced this error, as I am getting them continually? SRPT4653 VGW channel TN 008-00-09-07 (867) connected to farEnd 10.32.9.16:27668 TN 004-00 -00-14 (4c2) was closed incorrectly, current state = TxClosePending
  6. chrisay59

    MG1010

    Hi guys, guess I must work for a company that insists on using "cutting edge" technology, last month I was asking if people were using SIP Proxy Servers and MG XPEC Cards in the "Real" world, now I have another favour. I have just been given a job that is using MG1010s instead of the normal MGC...
  7. chrisay59

    Nortel SIP Proxy Server

    Guys, just a simple question.....is there anyone out there that is using a SIP Proxy Server to connect to the outside world whereby a carrier is providing you with SIP Trunks rather than good old fashioned ISDN/QSIG/DPNSS etc?
  8. chrisay59

    Nortel SIP Proxy Server Hardware Configuration

    Guys, a call for help, does anyone have any experience in configuring SIP Proxy Servers, I have a Primary and an Alternative to install and configure, I do not know even where to begin.....can anyone point me in the right direction, Nortel Docs etc.... Thanks
  9. chrisay59

    New Nortel MTX Card for Large Systems

    Hi guys, one of our salesman has sold a solution to a customer here in the UK, that uses the new Nortel MTX Card. This is supposed to go in 81 and 61 that changes a IPE Shelf into two MGC Cabinets, anyone used them, heard about them or know anything about them, because I can not find anything at...
  10. chrisay59

    HSP Cable Pinouts

    Hi guys, does anyone out there have the pinouts for the HSP UTP cable provided by Nortel, mine has got "lost" during a move. It is a xover cable however I have a feeling that the pinouts are not the normal ones?
  11. chrisay59

    HP COTS Server

    Hi Guys, I'm having a debate with Nortel ref HP COTS Server. I'm just using it as a straight Signaling Server but I need Element Manager as I have no CP PM Servers. I have only been sent the Rls 5.5 Sig Server Application CD. The NTP is really obtuse about the install as one NTP says boot from...
  12. chrisay59

    No dial tone CS1000E, Rls 5

    Guys, having a mare of a day. Putting in new HA System, did all configs as per NTP. Discover that I have No dial tone on Analogue, Digital or IP Sets. Can dial between sets fine, sets ring, however I have no ring back either. Have checked DTRs, XTD, Conf all as per book, FTC as per book for my...
  13. chrisay59

    Is it a fault or is it a feature - M2250

    I have a new site that has 3 x M2250 + SMILE Consoles, now imagine the scenario, an Internal Call Dials the Operator, he/she answer the call and puts that party on hold, during this time the calling party hangs up. They then pick up their hand set to make another call to discover they have no...
  14. chrisay59

    MWA Indication

    Guys, is there any reason why MWA shouldn't work on a Multi-Customer site using CallPilot?
  15. chrisay59

    Busy tone on Sets with VoiceMail

    Is it possible for a set to send back a busy tone to a calling party (Internal) before CallPilot kicks in? Reason I'm asking is because the customers wants to use ring back when free as well as CallPilot on all Sets. I am at a loss, as I can only get it to give one or the other but not a...
  16. chrisay59

    Siemens iDX to Rls 5 1000E - CallPilot Issues

    Hi guys have a really odd issue am trying to carry out a phased migration of users from a iDX to a 1000E. Have about 150 users on the E and 3000 on the iDX. When a users on the E calls another user on the E, CallPilot works fines, when a users calls in from a MOBEX extensions into the E and gets...
  17. chrisay59

    ISP 1100 Failure Rate

    Hi guys, just wondering if any of you out there are or have experienced a high failure rate of the ISP 1100 Sig Servers, I've just lost my fourth one in 10 months, all in seperate racks, all powered by UPS, all on good earths, when they fail I get the errors below! 27/02/2008 08:16:01 LOG0006...
  18. chrisay59

    IP Set Display Issues

    Hi Guys, just wondering if you have ever seen the following fault symptoms: Whilst carrying out a migration of 69 users from a BCM on to a CS1KE Rls 5 installation we started to experience the following: IP Set (both 1140E and 1120E) re-booted, DHCP IP Address allocated, IP Set Displays...
  19. chrisay59

    Release 5 Media Security

    Hi Guys, I was wondering if any of you out there that are using Release 5 have had an issue with Media Security. My problem is that I've implimented on the network and set MSSD to MSBT, all my IP sets have a CLS of MSSD, so they take their security setting from the Parameters as set in LD 15...
  20. chrisay59

    Using CallPilot as a VM for a Mitel sx2000

    Guys I'm at my wits end. I have a CS1000E/T combination running Rls 4.5, I have a Callpilot Rls 4 on the E. My task has been to configure 4000 mailboxs on the CP, however the extensions exist on the Mitel SX2000. My problem is that I ca express message to these VM Boxes and I get my MWI back on...