Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations TouchToneTommy on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: espen19
  • Content: Threads
  • Order by date
  1. espen19

    TelStrat T1/IPE interface box between SL100 and IPE remote shelf

    I have an SL100 with an IPE shelf remote. I have 2 LGC links going to the T1/IPE interface (Host) to a T1/IPE interface (remote) to the IPE shelf. Last Tuesday, the IPE shelf dropped. No power outage or weather caused this. I had no alarms on the T1/IPE interface cards which is odd because...
  2. espen19

    General PBX question

    Is anyone aware of software licensing on just a regular old PBX like an SL100? I have never heard of anything like it on a PBX, but a guy that is doing a survey for pricing to go IP here on our site is adamant that there is software licensing on this old switch and he can get cost savings...
  3. espen19

    Octel 350 using NetTerm

    How do I define a break key using Netterm? When I log into my SL100, I send a break with Ctrl + pause/break... When I try that using Netterm logged into the Octel 350, I get invalid character. Any help would be greatly appreciated.
  4. espen19

    SL 100 Question

    I have an Line alarm, but when I go into LNSTRBL, if gives me no information other than I have a critical alarm in LCM 3-0. I have gone back through logutil but can't find any info. Where would I find the issue here? Thank you for any help you can provide...
  5. espen19

    Intercom Group questions

    Is there a limit to number of intercom group members and also is there a way to mass notify an entire intercom group instead of 1 at a time. Thank you for any help you can provide....
  6. espen19

    can an 81C be tied in to PA system

    I was wondering if the 81C can be tied in to an existing PA system and if anyone has done this before. Basically we are looking to be able to pick up the phone, dial an access code and be able to speak throughout the building on an existing PA system. Does anyone have any experience with this...
  7. espen19

    VOIP questions

    I was wondering if any of you had any inputs on this. I am presently working on an Air Force facility that is going VOIP in the near future. We had a visit from CISCO last week. We are going to schedule a NORTEL visit in the near future, but I was wondering from some of you who have already...
  8. espen19

    System ID

    Is the System ID that you can change in LD 02 the ID that NORTEL understands as the Switch ID??? I am a DMS 100 guy and I am used to the NORTEL ID being set in the switch. \ Thank you
  9. espen19

    Programming SEB modem

    Does anyone have information on programming an SEB modem to dial out to a pager for trouble notification???? This was just dropped on me and I am not sure if it is possible or how easy this is.... Any help would be greatly appreciated.
  10. espen19

    Printing out NCOS list

    Is there a way to print out all numbers with a certain NCOS???? I can't seem to find a print load or anywhere else where this can happen. Can someone help out please. Thank you
  11. espen19

    setting up PROCOMM for option 81C

    I am trying to set up Procomm for direct connect into Option 81C and can't seem to get it going... Could anyone please help me out with settings..... Thank you
  12. espen19

    Setting up billing telephone number on PRI

    Can anyone help out??? I work on an OPtion 81C on an Air Force base. We are a small 1000 number PBX working off of the bigger SL 100 on the Air Force base. We are sending good digits to them for caller ID purposes, but when the phone number leaves the base it comes up with a generic billing...
  13. espen19

    XMI000 Errors on option 81C

    I have heard different things about this, but does anyone have any experience with XMI000 wither shelf 4,20 or 24 XPEC error #0001 or FPEC error #0001? I am new to the M1 and any error is kind of annoying. We get these sometimes 15 times a day. I was told by one guy that it could be missing...
  14. espen19

    XMI000 Errors on option 81C

    I have heard different things about this, but does anyone have any experience with XMI000 wither shelf 4,20 or 24 XPEC error #0001 or FPEC error #0001? I am new to the M1 and any error is kind of annoying. We get these sometimes 15 times a day. I was told by one guy that it could be missing...
  15. espen19

    call trace on M1 Option 81C

    Hey guys, I am new to the M1 and also to this group. I am a DMS 100 guy and have been on the M1 for 2 weeks now. I am having trouble locating call trace procedures in this little switch. Can anyone help out at all. Thank you

Part and Inventory Search

Back
Top