  1. trond345

    Deny Clip

    Would like to know if it is possible in TSW to prevent a certain digital extension from detecting the incoming external number? I tired KSCAC/ ADC/ D4=1,D3=0.D12=2 but no success. For some reasons the customer wants the extension to see "External" or "private" instead of the incoming number.
  2. trond345

    TSE 3.2SP3-10 LIMs system

    I have 10 LIMs system (TSE 3.2 SP3). some times lim 10 goes out of order due to network a prolem. the main problem is when LIM 10 tries to be back in service the ODD LIMs goes down. The ODD LIMs return back in service with out any action from our side. Is this a normal behaviour? Did any one...
  3. trond345

    CAS R2 CLIP

    I set up a CAS R2 route with the parameters below:(TSWSP6) ROCAI:ROU=6,SEL=0130000000000010,SIG=311110000050,TRAF=01151515,TRM=4,SERV=2100000011,DIST=30,DISL=128,NODG=0,BCAP=111100; rodai:rou=6,type=tl30,varc=00000000,vari=00002222,varo=00000556; KSCAC:DIR=450,ADC=00100000010000; The route...
  4. trond345

    TSW with remote LIMs

    Hi Guys, I have a critical site in an airport with 12 LIMs-TSW. 6 LIMs are connected to the group switch in the same room. The other LIMs are remote. the remote LIMs are connected to the group switch through the BIM transmission module. the customer wants to replace the BIM by a new...
  5. trond345

    Common Diversion

    Hi, I'm Trying CDCOI :INTDIV=0; (0-operator) to divert internal calls to the the operator??!! where I have the CDIV = 001151222; the calls never diverted to the operator or even to a hunt group!! when I try CDINI with modified CDIV it works fine..!! I'm trying for Digital and analogue sets...
  6. trond345

    Hot line between trunk access code and Extension

    I just created a SPEXI between a digital Extension and Analogue runk. The Extension has a limited access (calls locally. after making the SPEXI between the extension and the trunk access code, the extnsion has the ability to call locally, nationally, internationally!!! In other the SPEXI between...
  7. trond345

    Authorization code using Operator

    Hi, As I know that the Operator can't use central authorization code. The strane is that I have in the Call logging, some calls made by the operator shows that these calls made using Central authorization code. did any one experience that??!! The row data at the hyper terminal looks like below...
  8. trond345

    Paging

    I want to interconnect the TSW with a paging system through TLU80. It's clear in ALEX that it is not permitted to mix external lines with paging on the same board. I executed the procedure below: PAGII:DIR=400,MSAR=2,SCD=2,SSAR=0,PCAT=100...
  9. trond345

    Operator dbc 224hangs up

    operator attendants hang up frequently. This problem is observed on Dialog 4224 sets when we replaced the old OPI-II. Dialog 4224 sets are of R4C & R4E releases. temporarily fix for this problem is RFEXI. System release: TSWSP03 Board used: ELU28 NADAP; NUMBER ANALYSIS DATA TYPE...
  10. trond345

    walldisplay

    Dears, I have 4 wall dispalys, one as a master and the other three are slaves, the master and two of the slaves are working fine even the third is working , I mean i can see the messages I configured , but the background of the third slave wall display is always lighting(green),so the back...
  11. trond345

    High call rate

    Hi All, I have a solidus ecare4.1SP2 connected to MD110 BC12sp7, where i have two digital dialoic boards at the solidus side (60)channels connected by ISDN Q-sig to the MD110 for one of the of the GSM operators. I have the ALARM HIGH CALL RATE (CLASS1)? did any one face this before and how to...
  12. trond345

    MD110BC12SP7-AXE10

    Hi, I'm trying to connect MD110BC12sp7 to the AXE10 public switch through ISDN PRI. CNLIP.. says that the TLU6/1 is active SUSIP for that route says that these channles are free My parameters ROCAP:ROU=1; SEL=7130000000000010,traf=00151515,trm=4,serv=2110000010, sig=411110000030. Rodap:rou=1...
  13. trond345

    Conversation recording over DECT

    Dears, Did anyone try before to make conversation recording over DECT extensions? Is there any server based solution?if yes, How does the server connected to the MD110?
  14. trond345

    ECC stand alone

    Dears, I want to install ECC stand alone , but I couldn't find ECC stand alone folder inside the DNA 5.2SP3 CD. If I try to install ECC from the DNA CD without installing DNA the following message is prompted " DNA server is not installed", then I can't complete installation ECC. So my...
  15. trond345

    how to read IPU IPA number

    hi guys, is it possible to read the IPA number of an IPU using the IPUX mode? if not, is there aother ways to do so ? regards
  16. trond345

    3230 LPU disply

    hi guys, I have remote lim with 2 magazinez, each time i reload that lim, the LPU disply stuck at 3230 and nothing happens after that, i tried changing HW but still samething, is it HW problem or GJUL-GJUG connection or backup problem? plz advice
  17. trond345

    MD110 interface to public address system(loudspeaker paging)

    Hi all, I need to connect MD110 to an amplifier of an announcement system (public address system), I know if I use digital telephone with an option unit that my be a solution but I ma looking for another way, is there special interfaces in MD110 to do this? Plz advice Regards
  18. trond345

    CAS DTMF signalling

    Hi all, what is the TYPE that should be used for CAS digital trunk using DTMF signalling ?? MD11 BC12 SP6 thnx
  19. trond345

    clear signal problem

    hi all, I have MD110 BC11 SP13 connected with an IVR system using PRI Q-sig connection,there is also an AA system connected to the MD , the outside connection with the PTT were using analog trunks with the MD110, and this is the problem: when an incoming call to the MD on the anlog trunk...