  1. northwick

    Mapping luns to DMX FA for HPUX

    Hi I am mapping luns to a DMX FA for an HPUX host. The host currently has luns from a symmetrix 5 presented. When I map luns to the DMX FA should I use different VBUS, Target entries then the currently mapped luns on a symmetrix 5.
  2. northwick

    mirror limitation

    is there any way to get around the 4 mirror position limitation on a dmx.
  3. northwick

    Lun 0 Linux

    Is lun 000 still required for RHEL to scan all SCSI devices on the emc array
  4. northwick

    SRDF and BCVS

    Can you have and R1-2way-Mir-BCV established to an RDF1+Mir. Also the RDF1+Mir is in sync with the RDF2+Mir.
  5. northwick

    Connectrix Manager 7.02 Address ID error

    Running Connectrix Manager 7.02 with Mcdata switches. I have a host attached to a port which posts a large number of 'Address ID Errors' as seen via CM7.0.2 Any idea on how to troubleshoot this error. Cables have been checked.
  6. northwick

    HBA not logged in on FA

    Have an hba zoned to 2 FAs on a DMX. On one FA it is logged in successfully i.e Logged On Identifier type Node name Port name FCID In Fabric wwn Fibre Null Null 10002 Yes Yes On the 2nd FA its is not logged in...
  7. northwick

    ITC- Restore from second copy

    I have used ITC to create a second copy of the backup. The primary tape is no longer available. How can a restore from the secondary be handled. Is this automatic within netbackup of does the secondary have to be made the primary.
  8. northwick

    backup of w2k system_state

    I am trying to backup w2k system_state and get an invalid file specification error. Environment is nbu 5.0 mp1. Client software is normal w2k client mp1 - not advanced client. Anyone come across this before and how did you resolve.
  9. northwick

    segmented fabric zone conflict

    I have 2 12000s in a single fabric accross a DWDM link. Some zone changes have been made resulting in the event detailed 'segmented zone conflict'. This has been initiated by the zone changes not being saved 'cfgsave' and then the Control processors failing over. Any ideas on how this can be...
  10. northwick

    ISL and trunking activation - Brocade 12000

    I have ISLs in place. I would like to activate the trunking license. Will this have any impact on hosts access to EMC storage on activation. Thanks
  11. northwick

    NBAR fails to update clients

    I added some new clients into the netabckup configuration, however Netbackup Advanced reporter does not update with these clients. How can I get Advanced Reporter to update with these clients.
  12. northwick

    HPUX Lan Media and EMC BCV

    Anyone had any experiences with HPUX Lan media netbackup 5.0 mp1 and EMC BCV's.
  13. northwick

    Brocade ISL

    Can someone describe the steps involved in setting up brocade ISLs - switches 12000
  14. northwick

    Pend-TLD

    Have a drive in Device Monitor (NBU 5.0 Mp1) showing as pend-tld. Running SSO between 2 Media servers. Anyone know what pend-tld means?
  15. northwick

    SCSI Timeout NBU 5.0Mp1

    Currently experience multiple scsi timeouts running NBU 5.0 and a L700e storagetek. Drives are fibre attached. Is there a setting in bp.conf that can increase timeout levels.