I heard something that there is a way to make a back up of one NIU2 board on another NIU2 board, which is then placed out of PABX and kept as a reserve in case that active NIU2 board fails.
Is there some procedure for this ? Is it explained somewhere in Alex ?
It is BC12 in question.
Thanks ...
Can TLU 75 board be used as an analogue tie line, to connect two MD110 pabxes ?
Which signalling protocols are supported on each MD110 trunk boards? I can't find these informations in Alex.
Thanks !
Hi,
just as 1 year guarantee period has expired ... two out of four 4223 phones that we have at the moment started to work improperly. The same thing on both phones :
When I lift the handset I don't have an immediate exit on Line1, I have to press Line1 button. And also, to end the...
Hi !
A year ago we got some 15 patch panels installed in a new building and we are having problems with it since the first day. We are losing contact on all jacks at random, or when slightly touching the connector and testing showed that the loss of contact is due to the loss of signal on only...
Hi !
We have very strange problem !
The result of FIDAP command in cil folder shows two cil paths with no files in it, although we initiated cil function on hdu .
This is what it shows :
<FIDAP:PATH=/SYSN/USR1/ACS/CIL,OPT=ALL,
FILE/DIRECTORY DATA
PATH : /USR1/ACS/CIL...
Hi !
We initiated V.24 port as MML port and connected computer directly. It works when using it for sending MML commands by WinFiol, to PABX.
BUT, when we try to use XMODEM option to transfer a file from HDU to a connected computer, it won’t work !
We do the same procedure like over modem...
BC12 :
Is it possible to test network port which doesn't have parameter RPORT assigned ?
Tried with IOFTI but it asks for RPORT parameter ...
Do I need that parameter to pick CIL data on HDU through network port by using MDDT, because that is what I'm trying to do :)
Hi !
To start using network port, we changed IP address of network port with IONPC and then restarted NIU2 board with RFBOI.
Checking with IONPP showed that the change was accepted ( although IONPP showed it even before restarting ... but ok, who would know ... )
The problem is that we cannot...
I want to add key panel DBY 419 01 on Ericsson Dialog 4223 telephone. How to program keys on this panel in order to supervision some extensions ( LED is ON when that extension is busy ) so that secretary can visually know are some extensions busy or not .
Thanks
Hello !
We are currently using Cisco 1720 router with WIC - 1T card over KeyMile IDSL modem on leased line.
WIC-1T card --> KeyMile IDSL modem --> Umux -->Telecom leased line
We are now moving on new location where we can only use semi permanent leased line. Is it possible to connect WIC -...
Hi !
Which command and which parameter defines maximum charging cost for digital extension like parameter MCOST does it for analogue extension ?
Thanks
Hi !
We need to connect two DCEs ( multiplexer and NT modem) with X.21 interface.
On mux side there is DB25 connector.Using jumpers it can be set for X.21 and we have pinout scheme in that case.
On modem side we have DB15 port. I suppose standard pinout.
I know we should cross T&R and I&C...
Hi !
I'm sorry if the question is stupid, but I would like to know is it possible to do some initial programing of BC12 pabx with Alex BC11 or it has to be Alex BC12 ?
Hi !
In manual it says that installation of ID Caller Cards is available for KX-TD1232C only !
And we have KX-TD1232DBX !
Is there really no way to use ID Caller on DBX version?
just to be sure :))
Hi everyone !!!
We are having some (I guess older) Panasonic phones like
KX-T2365
KX-T2315
KX-TSC8MXW
KX-TS17MX-W
KX-T7030 etc.
and in user manuals it says nothing about can I change its flash time ? We want to set it on 100 ms (to be compatible with Ericsson MD110).
Do you know are...
Hi everyone !
We have some Panasonic telephones (KX-T2365, KX-TSC8MXW) which have flash time about 500ms. That is too much for MD110, so flash option (to transfer a call) won't work on these telephones.
We are soon going to have MD110, BC11 so I was wondering is it possible in MD110 to set...