We have a Public Safety/Inform 3.1 system. CLS, and Inform and SC servers and 5 loggers/NCF3's.
When we do a search in Reconstruction , the calls show up in the result window. When we click on them to playback, a red x shows up and a error saying " Server return no audio for this call"
I look in...
I have IP phones on Virtual loop 156 on a option 61 running 4.0 When I print the TNB for one phone it shows a type of SL1. I can't delete it as a I2002 , I2004 or SL1.
DES PPPP
TN 156 0 00 26 VIRTUAL
TYPE SL1
CDEN 8D
CTYP XDLC
CUST 0
KLS 0
FDN 5600
TGAR 1
LDN NO
NCOS 5
SGRP 0...
During MS patching on the CLS Server we stop CLS. During this time Inserter runs and puts the calls into the Inserter table .
Is there a way to stop Inserter from running until the patching is done and CLS is back up ???
Nice has two options. Live with the calls in the inserter table or delete...
We have two NRS's, one is primary and one is alternate. We also have approximately 30 Quintum ATA's that register to the NRS using SIP.
When the primary NRS fails or loses network connection everything should (we think)register to the alternate NRS.
All of our Nortel CS & sig servers will...
I have a small script that adds new NPA's in approx 25 pbx's. Once in a while the NPA is already in the database and I get a ESN072 error.
transmit "LD 90^M"
waitfor "REQ "
transmit "NEW^M"
waitfor "CUST "
transmit "0^M"
waitfor "FEAT "
transmit "NET^M"
waitfor "TRAN "...
I am trying to get a Quintum AS setup using SIP. We have 3 working via H323, but would like to get SIP working. Can anyone share their Quintum config ?
The NRS show that the quintum is registered, but when i do a CMD SIP STATUS on the quintum it says the primary registrar 10.x.x.x is not...
I built a very basic script to change the NCOS on phones.
;Recorded script. Editing may be required.
proc main
transmit "^M"
waitfor "TYPE: "
transmit "^M"
waitfor "TN "
waitfor "^M"
waitfor "ECHG "
transmit "yes^M"
waitfor "ITEM "
transmit "ncos 5^M"...
Does any one know the pin out of the RJ to 9 pin male adapter ??
This is for the reference clock cables for the NT5D12AH Dual T1 card.
I have a couple of QPC cards to upgrade tonight and it appears we don't have the NTCG03XX cables in stock.
I do have the RJ to DB9 male adapters.
TIA
We have a option 11c running version 25.30. Loop 6 / DCH 6 is connected to a CISCO 26XX with a VWIC-1MFT-T1 card.
It is a gateway for the CISCO IP phones. We had to replace the Clock Card on Loop 1 , and since then we are getting a PRI254 DCH: 6 DATA: 1 16 error
The gateway is configured for...