Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations TouchToneTommy on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: n6ber
  • Content: Threads
  • Order by date
  1. n6ber

    800 BRI

    I have not setup a ISDN line for some time and even then it was for data. Since I now have my Legend up and running at home it's time to dump the two 1MB lines and bring in a ISDN BRI. Reason, there is no way I'm going to pay $7 a line for caller-ID. The cost of one BRI is just about the same...
  2. n6ber

    Audible power supply noise

    I've got a 391C1 power supply that's audibly noisy. I've run into this with other switching power supplies and the cause is usually windings in the switching transformer that have gotten loose and vibrate. I've fixed this before but only on supplies that we build at a computer company I used...
  3. n6ber

    Carrier

    I have a Merlin II with a Legend R2 processor soon to be a R7V12 processor. Are there any issues using the Merlin II carrier or should I upgraded it to a 511A carrier? Already working on adding a 391C1 power supply.
  4. n6ber

    Mode codes

    I used to have a fairly complete list of the Legend mode codes for VMI but it's been a few years and I have no idea where they went. Does anyone else happen to have created or has such a list?
  5. n6ber

    Magic modules in a Legend

    I know that you can put Magic modules in a Legend carrier by adding a clamshell but can you go the other way and put Legend modules in a Magic carrier?
  6. n6ber

    Key system mode

    I'm used to setting up PBS/Hybred mode but not key mode. I using the system at home but the family does not like having to do parks in order to pickup a line from anywhere in the house. In key mode I think you just have to press the line button. They do like dialing 9 to get out on the pool...
  7. n6ber

    On-hook voltage, 012 and 016 modules, and phones

    Could someone tell me what the on-hook voltages for the 012 and 016 modules should be. I checked my 012 and it's about 20. The reason I'm asking is that I have a Panasonic Cordless phone/answer machine (KX-TC1890B) that's a few years old. This phone thinks that anything below 25 or 30 volts or...
  8. n6ber

    Can't seem to renumber a R2 system with a 2-digit dial plan

    I have a Merlin II systenmwith a Legend R2.1 prossor, that I maintained where I used to work. When they went CH-11 I got the system. Anyway, I reset the system back to a default condition with 3 cards in it so I could used it at home. R2.1 Processor 408 408 012 I have the basic system working...