Hi,
I have an existing site2site connection. How do I limit access from the remote net to certain hosts on the inside network.
I tried with a deny in the cryptomap acl but it does not seen to work.
As a test I tried to deny access to 10.10.20.50:
access-list outside_cryptomap_4 extended deny...
Hi,
I have a site-to-site vpn connection. It works fine from vlan 1 both ways.
I have a sub interface with a vlan. From this vlan it works to and from my inside network. I can connect/ping from the remote site-to-site vpn but not the other way.
Anyone here that can point me to the right...
Can't find trunk encapsulation option on my new 2960G (12.2) when configuring port-channel?
Did cisco remove this option? Is dot1q now default trunk encapsulation?
Thank you,
Morten
My vendor says that i'm wrong when I think that I used to get X records in my CDR. Now I only get N, S, E records. My vendor claims that an X record does not exsist.
Can anybody please verify if I am wrong or right?
If I'm right to where should I point him?
Would CDRX set to yes (LD 16) give...
Hi All
I have a problem. I have a MCR on several 2000's. I want this MCR (Emergency no.) to be transfered when unanswered. Is this possible?
Can I put the MCR on Key 0 on one set then make it MARP and control it in that way?
Thanks,
Morten
Hi
When I LOGO on our option 61c I get
TTY #02 LOGGED OUT 23:07 27/2/2004
SESSION DURATION: 00:00
On our option 11c I only get the > prompt. Can I configure the option 11c to give me "TTY #xx LOGGED OUT....." as response to the LOGO?
Thanks
Hi
When I connect to a service TTY on my option 11c I get the check in, check out messages from the PMS TTY. Can I stop the debugging/messages on my service TTY?
Is it possible to turn off all debugging (BUG/DCH/TFS etc.) on one TTY?
Thanks
Hi
I have a problem with some ACD phones (2008). When they hang up the "Not Ready" is activated and the phones are "Logged Out".
How can I prevent automatic log out on hang up?
Hi
I want to make a hunt group and made the following:
>ld 20
REQ: prt
TYPE: ght
LSNO 6
SIZE 6
RNGE
GHLN 0006
GHT
PLDN
DNSZ 8
STOR 0 3004
STOR 1 3000
STOR 2 3001
STOR 3 3007
STOR 4 3019
STOR 5 50
How can I define that when users dial...
Hello,
Can anyone help a newbie? I (think I) know that the following FCR is used for a route on our option 61C where we can forward to extenal numbers allowed by this FCR (what does FCR mean?). How do I add and delete numbers in this FCR?
LD 49
REQ prt
TYPE FCR
CUST 0
CRNO 9
CRNO 9
INIT...