I'm confused... the 470 doesn't support 802.1Q-in-Q (nested) VLAN tagging, so why do Layer 2 QoS filters seem to be processed before packets coming into a port are mapped into that ports PVID?
For example, I have edge ports that are configured 'Untag PVID', where the PVID is either 715 or 719...
So, on my old Norstar system I could have a line appear on more than one key on a set. The first call that arrived on the set would start it ringing and the indicator next to the 'first' line key would start indicating. When a second or subsequent call arrived and the first call was still in...
So, I'm at my wits end with this one...
We have two boxes: CALLPILOT and REPORTER. CALLPILOT runs on a 201i board in the CS1000 chassis, REPORTER runs on standalone 32bit Intel hardware.
I can access the Callpilot Manager via http://callpilot/cpmgr/ and all works as expected. I can also access...
I'm trying to locate a possible issue with one way audio on PRI based calls that are being bridged through a MICS 4.1 based Norstar. Ie. a call is coming in on PRI-A for a local DN and then being call-forward no answer (or busy) back out of the same PRI-A to a remote number via a different B...
I just tried to generate keycodes for a Norstar PRI enabler that I've had on the shelf for a while. I merrilly dialed the 800 number, entered the Express Routing Code and was met with a 'no such destination' error. Speaking to a customer service rep. I was advised that all activations are now...
I have been using a Fastrad II with NRU v10 for some time now. I have another MICS at a remote site and would like to set it up with remote NRU access.
I've been offered a Fastrad (not a 'II'). Does anyone know if there would be any issues between it and the MICS or NRU v10?
Thanks.
I'm trying to calibrate gains across a Channel Bank and through some devices on a private network. I have been given access to a 'Milliwatt' test line at my serving office - now I just need to understand how to use it effectively.
Am I correct in understanding that the 0dBm source should...
This is a two part question:
Using CLID capable analog trunk cartridges the MICS will support lighting MWI on specific stations using target line appearances and the 'Extl VMsg set' options. How exactly does it do this from the CO perspective? Is this just through the 'message waiting' bit in...
I have a MICS 4.1 with one T1, one 6 port fiber (non-combo) and one services cartridge in the KSU. There are also two LS/DS cartridges in the system, one in the KSU and one in a M12x0 cabinet.
The T1 is running as 24 E&M wink tie lines to another pbx, the KSU is driving 64 stations and the...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.