I've noticed network performance degrading right around lunch time for the past few weeks. I chalked it up to people enjoying their favorite soaps while they eat their lunch. Using Netscout I looked into it and I see many servers and workstations hitting an IP address 12.120.26.206. Lots of...
I have a Dell 2650 rack mount with Exchange 2003 on it. It has a mirrired set for the OS and 3 drives (RAID 5) for Exchange. It's getting close to capacity. All the drive bays are being used. Is the following a good plan of attack?
1. Do a full backup
2. Stop all Exchange services
3. Copy drive...
I'm running Exchange 2003 in a domain environment. A user mentioned to me that she had recieved SPAM from an internal user. This user hasn't been here for two years and her account was removed. How could this happen?
Since by nature the PIX ports are all closed and must be opened if needed is there any reason these statements are necessary?
object-group service denytcp tcp
port-object range 3127 3198
port-object eq pop2
port-object eq irc
port-object eq 37
port-object eq 81
port-object eq 123...
Just bought a 4503 Catalyst switch to replace an old switch. The fiber connectors on the new cisco switch are LC. The connectors on the fiber patch panel are ST. In the remote campus offices the fiber patch panel is ST and the fiber to ethernet converters are SC. Are there any problems with the...
I have cisco 1710 access routers at remote sites. The outside interface is connected to Nettopia DSL routers configured in bridge mode. The Cisco router outside interface (sh int) command shows Full-Duplex 10BaseT. Is this correct?
Thanks
We have a DMZ with a web server on it. Ports 1433 1434 and 1435 are open. When you hit the web page a logon screen appears. When you key in your user name and password an error message comes back saying it can't find the SQL server. Is this a port issue? Which port should be open to pass the...
BE 9.1 doesn't support the Exabyte VXA-3 drive and may not. I have it configured to emulate a VXA-2. I can't get BE to see it as a robotic library. What drivers should I use for the tape drive and what drivers should I use for the Medium changer in device manager?
I have 2003 DC that is really slugish. It takes forever to respond to anything. In the task manager it shows lsass.exe pegging the CPU at 90 + percent all the time. I ran the process from MS and verified that it is not a virus. What is this thing?
The Cisco references to enabeling HTTP on my 4503 switch don't work. The SET command is very limited to only memory settings. I do not have the CatOS installed, just the IOS 12.2.
So can I enable http server without having the CatOS installed?
Are there any major implications if I keep my OWA on my Exchange server inside verses putting it on a server in the DMZ for the purpose of people being able to access their mail from outside?
I'm trying to add a static statement to my PIX515e as follows:
static (inside,outside) 150.176.6.142 192.168.1.86 netmask 255.255.255.255 0 0
I have the access list as follows:
access-list FROM_OUTSIDE line 96 permit tcp any host 150.176.6.142 eq https
As soon as I add the static entry, my...
I have my new Exchange 2003 server up and running with the old 5.5 server still needed for the Internet Mail Service. I would like to eliminate that part and route mail from 2003 via creating a new SMTP connector. I found a really good how to article MS Article ID 883407. The questions I have...
I am running 2003 server on all servers. At the data center I have two DCs that are Global Catalog servers to avoid the single point of failure as recommended. I also have 17 remote sites connected via 768 DSL or T1, each with a single DC. Should I have the DCs at the remote sites as Global...
I have a Cisco 3002 VPN router that loses inside and outside connectivity precisely, to the second, every 16 minutes. It must be restarted to gain connections again. When it dies you can't ping it from the inside or the outside. Is there some kind of setting to turn off?
Weird huh!!
I have a VPN client 3002 router that keeps dropping in the field. The local user must power cycle this device and the VPN tunnell is established again. It goes down about every 5 to 10 minutes. Is there anything I can do to keep this from happenning?
Thanks in advance