I have looked at thread798-1289561 and my problem is that I have MM on a 81c and the message is every 1 min; this has been going on for sometime now and I have sysloaded the switch a few times since. I only have one active AML port which is for MM. Does anyone have any suggestions where I should...
I HAVE EVERYTHING SETUP CORRECTLY FOR CALL FORWARDING BUT MY PROBLEM SEEMS TO BE NO FREE LINES WHEN DIALING OUT WHEN THE CALL IS FORWARDED OR TRANSFERED. I HAVE A PRI WITH 20 DIDS; LINE 145 THRU 164. THEY ARE ALL TARGET LINES. LINES 001-023 ARE ON PRI-A BUT ARE UNABLE TO GRAB A UNUSED LINE TO...
I think I have one that will stump most of you; I have ICS 4.1 system with a PRI programmed for NI2. When I forward a desk phone to a cell phone and 4 digit dial that ext. from another set on the system the call is forwarded out of the switch correctly and call is completed to the cell phone...
Over the past 2 days I have had some of my printers LPR ports just disappear. It appears to only be happening on two specific subnets. The next day I have to go back in and recreate the ports. The printer names are still there. All my other printers seem to be fine. There is nothing I can see in...
Does anyone have any suggestions where my problem might be?
On my attendant console my LDN Data for LDN0 is 7000 and my ANI_DATA is ANAT 353 AND ANLD 7447; when calls are placed caller ID is showing the 7000 LDN and I need it to show the 353-7447. Anyone have any suggestions.
Is there anyway to configure a ACD Queue to forward to another number after a specified number of rings? I know I can NCFW but that treatment does not allow the queue line to ring.
I was wondering if anyone knew exactly what card this BERR error is mentioning?
Thanks,
% BERR704 EXC 0: Bus Error in ISR
% SR=0x2700, PC=0x10f35c32, Addr=0xb000c140, SSW=0x105
Anyone know what the NTDK26AA (Option11E to 11C Convertor) would be used for? I will be performing a upgrade from a 11E to 11C Succession 3.0 soon and Nortel shipped that card as well. I can't seem to find a need or a use for it in my upgrade. Anyone have a clue?
I have a path built for external transfer setup on line028; these are centrex lines which require a 9 to dial out. I have configured line028 as PUBLIC but when I call the CCR and press option 5 (external transfer)I recieve a message that states that the line or line pool is not configured for...
I have centrex lines coming into the MICS 4.1 which require a 9 for dial out access, but when I push intercom I have to dial 9 and then I'm transferred to an available line in my pool and I have to dial 9 again. Does anyone know how I can strip one of those nines off.