Hi, all!
Please, how to set "presentation restricted" on analog or digital port? For example, we have ext. number (local port) 3543, and for external calls through PRI EDSS1 we should have in SETUP message Calling Party Number (CgPN)=3543 and CgPN Presentation Ind.=Restricted not Allowed. What...
Hi, all!
We unmount HDD with MD110 backup from HDU7 board, connect the HDD to PC ATA-bus. Windows detected the HDD but not its file system (MD110 backup), read that the HDD is unformatted.
May be we should use Linux? Or another way to read/write the HDD.
Thanks.
Hi all!
The phone is parked:
susip:dir=5909; STATUS INFORMATION AT 15:19:13 21FEB08
DIR TYPE TRAFFIC STATE/PTR LINE STATE/PTR DIV STATE ADD INFO
5909 ATS PARKED #0275 BUSY #03D6...
Hi, all!
We have BC9, and CDIDP:
DIR---DIV
1000--1001 it works on no reply
1001--1005 it's not, i.e.:
We call 1000, phone rings, no answer, after a while calls rerouted to 1001, phone rings, no answer, but, after a while call is not rerouted to phone 1005. How can we solve the problem?
Any...
Hi, all,
simple question - if md110 works as only transit station, e.g., 3 PRI EDSS1 - the law of 11-12 calls in 10 seconds and no more or alarm, works or not? Can it carry the load upto 100% ?
Thanks
Hi all!
BC9 CNI76, modem BYB2424 in MAG0.
History:
1. Access through modem was right, worked.
2. After failure MAG was changed from LBP17 to LBP20.
3. Access through modem is not right, not worked at all.
STUNI/STTSI/STRAP gives NO SIGNALS FOUND .
Program units TWP2, ICM were restarted...
to whosrdaddy et al
A question about copyright - can we reproduce some ourselves edited topics from this site at our private sites not for sale edu only? For example, in word version, converted to html?
Hi,
how can we regulate A-number presentation (displaying) on system digital phone display? Digital phone connected to ELU28, BC9 CNI76.
The matter is that we receive IAM message with two fields - Calling Party Number and Generic number. The station (BC9 CNI76) displaying Generic number. Can we...
Hi, all!
BC9, CNI76, 1-LIM system, single (non-duplicated) control system, 2 TMU in LIM:
We had alarm "324 FAULTY TMU BOARD" on one TMU & "62 BUFFER TRANSFER HARDWARE FAULTY",
FTTDI, FTMDI give NOK, well, BLDBI, CNBOE for faulty TMU, second TMU is O.K., but "62 BUFFER TRANSFER HARDWARE...
Hi,
Preamble :) : when we go off-hook and then no dial, the system waits 8 seconds, then sends three-tone.
Question: is it possible to set this timer to, for example, 16 seconds? Or this is prohibited for PABXes as class due to common resourses limitations?
Thanks,
HIREI
Hi,
is there a service to reroute incoming call to local MD110 number by pressing the key on your DBC phone just watching the A-number blinking on display (in the on-hook state, of course).
Thanks.
Hi,
pls, how to read ECF Number from MD110 terminal? MD110 BC9 CNI76. Command SUSIP gives us the fact the ECF is used but not the external number.
For Follow me we get the fact and the number: FME=DIR in Additional Info.