thread798-1637211
I have an OP81C running Succession 5.0 and a Cisco Call Manager Cluster (8.6.2) in a CDP configuration. The PBX has the PSTN connectivity and all Cisco phones are DSC's in the PBX. I recently had to change the T1's configuration between the PBX and the Voice Gateways from QSIG...
I'm trying to access a Paging Trunk on a Meridian 1 from an IP Phone on a Cisco Call Manager. Both systems are tied via a PRI. I have the same setup elsewhere and it works fine but on this particular site, I have no audio when accessing the Paging trunk... Here's a TRAC of both Paging TN's;
Not...
We are using Release Link Trunks for our Centralize Attendant Service and since I'm not very familiar with this type of trunk, I'm not sure where to look to solve my problem... When a user dial "0" and ask a transfer to "911", the CAS operator can't transfer the call as he gets a "Fast Busy"...
I have two OP11 mini with an MC32 cards which I can't retrieve the configuration info through OTM. I added a site in OTM, added a system for that site and then tried to retrieve the MC32 info but I'm getting "wrong SNMP read/write community name". These two OP11 were sent to me supposedly...
I'll try to make a long story short... I have an OP81C with Megalink to the PSTN and Autovon trunks. I have an OP11C with a PRI (tie) to this OP81C. In the OP81C, I have ESN configured with 89 as AC1 and 86 as AC2.
In order to use VNR in the OP11C, I had to turn on ESN so I did using the same...
I have an OP11C tied to an OP81C via a PRI. The PRI comes up no problem but one of the DCH (in OP81C) is "RLS CTS DOWN" and the other one (in OP11C) is "RLS NO RESPONSE". As far as the loops are concerned on both side, everything is green and no alarms. Every CH on both sides are MBSY, which I...
Warm start - reason 36.
I'm having this problem where my OP11C warm start for absolutely nothing (warm start reason 36). I changed the SSC card as well as the S/W daughterboard (NTTK25), which fixed the problem for a litlle while but then the problem came back. I don't know where to look...
I get a SCH1392 when trying to program a MCR DN on a 2616. I'm getting the SCH1392 sch code but can't find a description anywhere!?!? Can anyone help?
Thanks
I recently noticed that in front of some incoming calls from the PSTN, we get and "H" in front of the calling number, ie: H5147803456. I have seen this H before between two PBX's tied with a PRI in a CDP configuration but never from the PSTN on a DID route (Megalink). Any idea anyone?
Thanks.
I have a 2616 with two MARP DN's. With 5300 (key 0), no problems, calls will go to mail on a Busy or No answer. But with 5624 (key 1) calls will go to mail on a No answer but not on a Busy. Instead, you hear a message "the line is busy, please call back later". Both DN's have their own MailBox...
When a user transfers a call to an internal extension and that this extension doesn't answer, instead of going to Mail, the call is released.
Any idea anyone?
I have 3 Meridian OP81C with Autovon routes. From the first switch, I call the second one through an Autovon route and then redirect the call to the 3rd switch through the same Autovon route. The ACDN in the second switch is NCFW to a number in the third switch. The problem is that the call gets...
I have a MICS 2.0. I want a 1-800 number to ring simuletaniously on 4 sets. Since I'm kind of a newbie to the Norstar world, I would like to know if it can be done. I have been told that I might need to upgrade to MICS 4.0 in order to achieve this.
Thanks in advance!
I just started using NRU 10.0. When I connect to the RAD (operator assisted method) on a MICS 2.0, I do connect but then I get "RAD password rejected" . I opened up Norstar Manager 1.1, connected to the RAD, verified the password and it's good. Why is it rejecting the password with NRU 10.0...
I have an OP11C tied to an OP81C with a DTI route (rte 61).
In the OP11C, I setup AC2 as 9 and then under AC2, an SPN of 911 which is routed to the OP81C through RLI 9. RLI 9 points to a DMI 9 which is setup to delete 3 and insert 6009 (6009 is a DN in the OP81C).
I have a DSC of 6 in the...
Can anyone tell me how I can change the parm of a D/L DCH on a TMDI card? It is at RS232 and I need to change it to RS422 but can't find the prompt in LD 17.
Thanks!
I have ISDN PRI to PSTN. The CLID comes in OK on digital sets (M2008 etc...) but not on analog sets like M9316. I have a CLASS MODEM card installed. From set to set, the DN and NAME will show OK on the M9316 display but for an external call, it's the VM number that shows up on the display. Any...
I programmed up and ESDN 911 in LD24 and setup an OSN key on a set and it all work fine. I only have a question about DFCL (Default ESA calling number). What is this number used for exactly? Is this the number we want to appear at the PSAP?
Thanks Matt.
Maripaq
I have to implement ESA on three different OP81C. For 2 of the 3 PBX (lets say switch A and B), the 911 calls need to go to the city PSAP and an OSN has to be programmed. For the other one (switch C), the 911 calls have to go to a local phone on site. On the 3 PBX, AC1 is 89 and AC2 is 86. I...