My questions is as follows. Is it possible to run NLB on two servers in a DMZ on a pix? My concern is that if an external host connects to the virtual IP of the NLB, which is a NAT and that request gets sent to server "A" does the server reply with the NLB virtual IP or the host of the same...
Ok. Firstly let me say I know this is the most elementary of topics for those well versed in LAN/WAN networking. Up until today I had believed that an ACL configured as either a permit or deny statement with 10.10.15.128 0.0.0.127 would deny/permit everything from 129 up to 255. I've learned...
I have this on going disagreement with our Windows admin about DHCP. My preference is run DHCP on the switches but he says it's a function of a Windows server. I'm trying to make an argument to take over dhcp but have only come with "it will save spare the network of broadcasts". Also that it...
Anyone know if it's possible to have more than one speed dial number assigned to a 7940? I'd actually like to setup a speed dial list but that doesn't appear to be possible.
Question is, how do I assign an IP to a Gig ethernet interface. When I do this, am I in effect converting the 2950 to a layer three switch? I have removed the " switchport" function of the interface The switch will support 9 PCs and have a connection to a 2801 router that has a four port POE...
Need help with setting static ip. I need to set a static ip for a host. I know how to do it on the host. How do I determine what ip addresses are available to me in my subnet and then set it static on the layer three device that has the dhcp pool? (need commands). Thanks.
Need some input here. I am trying to take an inbound call that gets delivered to the switch on a PRI. I am trying to take the did (7 digits get sent from C0) and convert it in the IDC table to an acd dn that has a no answer call forward to a route access code. For example, telco sends 1234567...
Can someone explain what the number in parenthesis is? See prt below
NPR000
.FSUM
**M3902 SUMMARY
080 - ON DISK
**M3903 SUMMARY
080 - ON DISK
080 (017 ) - 000001 SETS FOUND
083 (024 ) - 000001 SETS FOUND
**M3904 SUMMARY
083 - ON DISK
083 (024 ) - 000035 SETS FOUND
083 (018 )...
When statting the system monitor I recieved the following message from the switch.
# Program 37 identifier. No action.
.STAT XSM
IOD300 0
# No response received from System Monitor (NT8D22) after sending status
# request message.
How do I troubleshoot this problem?
Would someone please explain to me how FCR and FRL are used. I would also need the related loads to configure them. I used to know this but have forgotten. Thanks.
Here's my problem. I have a point to point DS3 between two of our sites that provides 14 T1s between to centers. At one site we have an Opt 81 and at the other a Rockwell Spectrum ACD. When we experience an outage on the DS3 the T1s come back in service on both ends but the on the Nortel the...
Does anyone know which load/loads to use when configuring an ITG card? How many IP addresses does each card require. Any information would be a big help.
Looking for suggestions on what would be a good maintenance routine to run on a daily basis. I am talking about what I should "stat" on the system. The more detailed the better. Thanks.