  1. eyal1975

    How to set fax extension in Intuity Audix

    Hi, i have intuity audix system. when i get fax to my mailbox, there is an option to send this fax to fax machine. when im trying to enter the fax number, the system tell me that it cannot be send. do i nedd to configure the fax extension in the system, and if so where it should be configure...
  2. eyal1975

    Avaya CMS

    Hello, There is CMS system that works with operation CSI PROLIGIX, version 10.0 How can I change the INTERVAL INTRAHOUR in database items calculations (for example: change to 15,30,60) Administrative data: administered on the switch or on CentreVu CMS. For example, the database item...
  3. eyal1975

    Integrated Managment 2.1

    Hi, i just installed Integrated managment 2.1 with linux server. when im trying to start the proxy-agent, i got error message " applicaion file error". i tried to uninstall and reinstall and i got the same problem. any idea ..... >???? Eyal
  4. eyal1975

    Modular Messaging

    Hi, we buy new modular messaging system Rel 2. the equipmment include MAS & MSS. the cnfiguration should be integration with microsoft exchange. someone know if rel 2 support this integration, and if i need Both MAS & MSS. Eyal
  5. eyal1975

    Time zone on Intutiy Audix

    Hi, i have Intuity system rel 4.4 with old definity si rel 6. when the caller got his voice mail (from the phone) he recived the coorect time and date. but, if the message came from pop3 account, the time that shown in the mail is diffrent with 7 hours. i tried to change few time zone...
  6. eyal1975

    Definity Modem

    Hi All, my customer have Definity si rel 6 system. the modem configuration for remote access is configured for internal modem. when the line is coonected to the system\, the line is always busy, and i think the interface on the system is bad. i want to know if someone has this problem in the...
  7. eyal1975

    G150

    does anyone know something about G150 media gateway ??
  8. eyal1975

    4610 personalized ring

    Hi, why there is no option in the 4610 ip phone to choose the type of the ring. in the 4620 there is an option to choose 1 of 8 types of rings any idea ?? Eyal
  9. eyal1975

    IPSI Question

    Hi, I have few questions regarding G650/G600 and IPSI card. The system that I am using is S8550 with G600 (using Ipsi2 TN2312BP) 1. The IPSI card should be in slot 1 or 2? 2. If I configure the Card location (in the display of the card), the IP address of the card lost after 30 sec, but...
  10. eyal1975

    IPSI card problem

    Hi, after configuring IP asddres to IPSI card, all the information lost after 30 sec ( default). i tried many times to set it again, but it happends all the time any ideas ?? Regards Eyal
  11. eyal1975

    How to enable Telnet to Intuity Audix Lx

    Hi I have Intuity Audix Lx system the telnet is disable by default, someone know how to enable this option ? regards Eyal cohen
  12. eyal1975

    How to install wallboard

    Hi, I have BCMSvu application with wallboard type iw1. I have problen to connect between the wallboard and the pc. I know that the address of the wallboard is 01, and the type of the connection is RS232, but i dont know how to change it in the wallboard. if somone already set this connection i...
  13. eyal1975

    Audix Question

    Hi, maybe somone know,if there is an option while call came from extension with busy coverage to the audix and hearing the Busy greeting, i want to add option to the caller to prees 1 to hold for this extension, or 2 to leave message or 3 to the operator. any idea ?? Eyal
  14. eyal1975

    How to change Security code to station ?

    Hi i configured feature access code : change security code but when i enter the access code in the phone (*40) i get error tone that i have no permission to change it. where is the configuration need to allowed this access code ? thanks alot Eyal
  15. eyal1975

    Feature Access Code

    Hi All, i have ip phone type 4602 (without feature buttons), and i want to configure feature access code to call back somoene that call me and i missed the last call ( like calling from call log- miseed call ) any ideas ? Eyal Cohen
  16. eyal1975

    Caller ID in Co trunk

    Hi All, someone know how to configure Co trunk with Incoming caller id ? My pstn provider send me the caller id information. i saw in the document only 3 kinds of protocols "BELLCORE , NTT , V23-BELL " that supported in the u.s and japan. is the S8300 Server rel 1.3 suuport incoming...
  17. eyal1975

    How to use Toll Restriction

    Someone please can help me to understand how "All Toll" working? in the cor & Toll list thanks Eyal
  18. eyal1975

    How To configure DID in Tie Trunk

    Hi all, i have tie trunk using TN760E , the type of the trunk is : E&M type 1 wink-start. i know that i can Use did digit conversion like in ISDN trunk. for example if i have call incoming from the trunk ( from another pbx), and the digits that sent is 2000 , i want to send the call to extension...
  19. eyal1975

    How to set trap from prologix

    Hi, i have definity prologix rel 11. i have Hp-open-view system that manage all my networks device. i want to send traps to the managment system or to check the status of the system with MIB what i need to configure and where ? thanks eyal
  20. eyal1975

    How to make queue on trunk

    Hi all, someone know how to queue on trunk ? like auto callback on station. i need this for example, when station calling outside the office and and the trunk is busy, i want the station ring when the trunk is idle any ideas ?? Eyal