  1. nscripta

    Unable to get number to convert CLI (MX-One) for outgoing call

    I need to modify a couple of analogue extensions on a MX-One Telephony Server to send a different number as their CLI to the terminating exchange. At present the DDI number is sent as the CLI. I have tried to add this facility using the number_conversion_initiate command with various parameters...
  2. nscripta

    DDI calls divert after 6 ring to CFNA number but nothing for CFNA in programming, how?

    Three digital phone which accept incoming calls on a ddi route are diverting after 6 rings to one of the 3 prime numbers, display on diverted call phone states incoming number label and "CFNA". All three phone have all their forwarding functions (EHT,FDN etc) set to the their own prime number...
  3. nscripta

    Is there a meridian equivelant of the md110 pc-regen application

    PC-Regen for the md110 exchanges generates an exchange rebuild file by requesting multiple print commands, analysing the information and then creating the command list necessary to duplicate the configuration. Is there an equivelant application for the meridian? I am looking to test some...
  4. nscripta

    SCH5222 Error Code when adding hotlines, tried new tn workaround but no success

    Changes carried out to an option 11c to add both way hotlines to existing digital sets caused multiple 5222 errors to be displayed. A search on tek-tips forum indicated that it can be associated with the template and users have reported success if a new DN is created and then add the hotlines...
  5. nscripta

    DID (DID) display format on digital phone, can it be configured?

    Incoming calls presented on our DDI -trunks do not always display a name, however always show the trunk label and digits received. The name display is directly associated with the number received. Is the name display dependent on what is being sent from the public network? (DAS) Or can The name...
  6. nscripta

    Will a permanent call forward to an external number on a 500 set allow both way hotline external

    Trying to get the equivelant of both way hotline working involving an external number. Would a permanent call forward to an external number which is programmed as the remote destination in a HOT D key configuration allow both way hotline to be achieved? The external number already dials a...
  7. nscripta

    Both way hotline to external number, incoming as DDI to SCR, can it be done?

    Looking for a solution to get both way hotline working on keys on a digital phone. At present the keys are programmed as an SCR, the incoming calls are presented by BT over an ISDN30 link effectively as DDI routing, with the last 3 digits sent to match with the key presentation. Is there a way I...
  8. nscripta

    Generic Exchange Comms Application available (serial port connection) - VB.Net 2.0 runtime required

    Any time I need to access a Meridian I can't remember the command sequences so I have now developed my Exchange Comms Application. The app provides a means of creating sequences for dynamic buttons which are loaded from their respective files on startup.(buttons directory) The app can be...
  9. nscripta

    Can you identify the D (number of digits) parameter for a hotline from a printout on a digital phone

    I am developing a vb.net app for programming keys on digital feature phones (we don't have MAT or similar). I can populate my textbox controls with the key contents however need to know the number of digits for the D parameter on hotlines. Is there any method to obtain this parameter or do you...
  10. nscripta

    MAT - Can the dongle be transferred between option 11 switches?

    We have a meridian option 11C that requires bulk changes to be made to the digital feature sets. Unfortunately the MAT pc for the site is no longer functional and cannot be repaired. Is there a method whereby a redundant MAT pc and dongle can be configured to function with the working option...
  11. nscripta

    Hicom 330H - What will be affected by soft restarting exchange

    We have a Hicom 330H used in a bespoke configuration where we have received specific training by Siemens to carry out basic functions e.g. card swaps, circuit moves, backups. There is a fault on the system at the present time where the exchange is running from the MO drive and the hard drive is...
  12. nscripta

    Hipath 4000 - add analogue extension - set as hotline

    Many years ago I attended an o&m course for our bespoke hipath 4000 which has no nirmal dialtones, all extensions are configured as hotlines. I have with adding 2 new extensions and configuring them as hormones.Can someone point Mr the right direction? The last time I hastily do something...
  13. nscripta

    DSCXL ADP Card - Error 9

    Hi all, I am trying to remotely assist a technician on a fault involving a remote Hicom 300 that is displaying an error 9 on the DSCXL card (ADP). I have looked at my course notes from many years but there is no reference to the SSD-display other than the A - active and S - standby. Can someone...
  14. nscripta

    2MB PRI remains in 'starting' mode - no obvious alarms

    A network of six option 11c configured in a ring has been reduced to only switches with two point to point links. One of the links was part of the original original ring configuration and is working correctly, the other link is routed over the customers sdh network and does not function...
  15. nscripta

    Meridian Option 11C - Fibre Expansion Cabinet Problem

    Hopefully someone can work out an error in my installation.. I have changed an existing Meridian Option 11C installation as follows: Previous Set Up: Software Version: 24.55 1 * Meridian Option 11C with one NTDK80 fibre daughterboard. 1 * Meridian Option 11C with fibre receiver card New Set...
  16. nscripta

    Hicom 300 - defining a hotline for an analogue extension

    I have been tasked with adding 3 new analogue telephones to an existing Hicom 300 that require to work in a hotline configuration (All the analogue circuits work in this manner). The problem is as far as Hicom is concerned I have forgot most of the information from an Operation and Maintenance...
  17. nscripta

    TNS count in SLT doesn't add up

    In order to add further extensions to a multi-cabinet option 11C I examined the system limits, to which I obtained the folllowing information. >LD 22 REQ SLT TNS 750 LEFT 170 USED 580 ACDN 200 LEFT 200 USED 0 AST 200...
  18. nscripta

    Option 11C - Identify fibre daughterboard without shutdown

    Is it possible to identify the type of fibre daughterboard and other relevant information for an SSC card on an option 11C exchange by using commands only, or it necessary to physically examine the hardware required the equipment to be switched off? Nscripta
  19. nscripta

    Meridian Option 11 - Remote Divert by feature - How??

    I am trying to find a way that exists on other exchanges whereby a designated telephone can remotely invoke/cancel a divert that is active on a designated extension by using a feature code sequence. Examing the meridian documentation the only mention I can see that does not fully meet the...
  20. nscripta

    Is there a method to define the DN range on the Meridian?

    Having looked at all my documentation (is was a few years when I attended the Nortel courses!!) I cannot find a method that defines the directory number range. What does the command LUDN interpret the determine the unused directory numbers? As part of an install I was adding a DN, however it...