  1. hughiepal

    configure remote modem? AT commands.

    Hi, does anyone know how to configure a modem at the remote end ie that it answers and connects to the Md110. How do I clear the AT commands already stored in it. What commands should I put in it and how do I store these commands so that even if the modem is powered down, they will remain...
  2. hughiepal

    incorrect of a Lim from a system.

    Hi --- My Problem - I maintain a 15 Lim system BC9. One remote lim (call it X) was removed from the system by an outside company. This was not done properly, PRINT commands did not work. eg EXDDP:dir=all; resulted in wait wait wait COMMAND LOST. Other print commands resulted in "LIM X IS...
  3. hughiepal

    group switch problem!

    Hi, I have md110 bc9.GSM 0 and 1 are duplicated. Two GJUG5 cards are strapped for G3 mode.ieGJC 20 - 23 and GJC 24 - 27 .Only one lim is on each GJUG5. If GSM 0 side 0 is active, LIM 17 goes in on GSM 0 side 1,GJC 24 and comes out on GJC 25 towards GSM 0 side 0 GJC 24 (works ok) But!! Lim 16...
  4. hughiepal

    hunt group

    Hi I have a little problem -- I have a hunt group set up which is supposed to divert to Octel voice mail on busy or no reply. The group is set up so ------- ghdap:grp=1234; ghdap:grp=1234,serv=1000,sel=100,que=0, The group has 2 members. the group has cdini to voicemail. problem --- On internal...
  5. hughiepal

    Group Hunting

    Hi, My switch, Md110 BC9, will only allow an extension to be a member of max 4 hunt groups. Is there a parameter to modify this? Cheers
  6. hughiepal

    LCR

    Hi, I'm setting up Least Cost Routing. The parameter description states that up to 20 digirs can be entered on the PRE setting - I seem only to be allowed 10 -- anyone know a fix. Cheers
  7. hughiepal

    Synchronisation

    Hi, I have a 2 Lim system without Group Switch. The external synchronisation is set to Lim 2. Lim 1 is the i/o Master Lim. 'Alex' states the synchronisation must be taken from the I/O master Lim. Does anyone know what problems this can cause. Cheers
  8. hughiepal

    Hi, I have to end a digital extensi

    Hi, I have to end a digital extension but I get the message "Dir has RAC" - any ideas - also , what is FCN - CLT, cheers hughiepal
  9. hughiepal

    AAU2??

    Hi, does anyone know how to connect and configure an AAU2 card. I believe it is designed to report alarms over an ethernet connection.