Outgoing calls placed on SIP trunks disconnect at fifteen minutes and thirty six seconds.
Pick up a shoretel IP480G set and dial a telephone number. At the 15:36 mark, the far end drops but the trunk test tool and communicator (I have not looked at the icon on the telephone set yet) show the...
Hi,
Have a problem, users complaining conference calls getting cut off. I log into the switch and find these bug errors. While they are not coming fast and furious, they are at a steady pace.
BUG1500
Parameters to NUM_DN_MEMBERS do not identify a valid SL-1
DNBLOCK. Procedure NUM_DN_MEMBERS...
CallPilot 600R 5.0 patched with SU11 etc.
So I have just spent a couple hours in the lab trying to figure this thing out.
It used to be when power is applied to a CallPilot 600R server it would automatically power up and start. All services would load and the CallPilot would start processing...
Opt 11 running 3.0
Nars/bars NOT programmed. Using unr and CTD in set class of service to set permission for long distance.
PRI using NI2
Trunks are programmed for two way DID
Cannot dial international long distance from this system as somewhere in the PBX it is stripping off the 011.
I...
I'm looking for an on line version of the old northern telecom vantave 8 and 12 manuals. I do have the printed version, I would just like to avoid the photocopy and fax routine....
Thanks
Some people are like slinkies...not really good for anything, but seeing one tumble down the stairs makes...
on an opt 11c is it possible to have a contact closure while using the trunk port configured for paging?
I guess an example of this is on the norstar system, once you access the external page port (audio) there is a separate port that provides a dry contact closure to activate features on the...
opt 11c
version 2111
release 22
issue 8 D
ERR4286 12 (message count on the loop exceeds the threshold value)
FHW0003 12 (loop n has been detected as faulty by loip function ini000 0006 has been averted)
After several warnings with the ERR message (period of three hours or so), The FHW message...
err4286 12
Message count on the loop exceeds the threshold value.
Action: refer to any OVD messages previously printed, and check the hardware for defects that generate an overload condition. Rearrange the tn's to another location or they may be disabled. Reconfigure the loop...
Customer wants to set up his system to block call line id from being sent to the party he is calling. He is using ground start COT trunks. This can be done one of two ways. Call the telco and have them block the info at the CO (for a fee) or dial *67 before each call.
I have tried digit...
I need to set up my pc to program meridian mail remotly. Unfortunatly I don't know how to set up the soft keys (logon, etc.) Is there documentation available that would detail this? I have searched through helmsman with no sucess.
I have a site with a reach line card and a remote office 9150.
The opt 11 (and the reach line card) is back east and I am out west with the 9150. The customer has two 56k lines running east/west one for data and the other for voice (9150).
When I had first arrived on site the cisco 2600 router...
I have taken a backup from one opt 11c (ld 143,xbk) and have restored on another opt 11c (ld 143, xrt). I am then given a prompt:
R>CBKP011 Site ID in backup image differs from that of the switch.
What do I need to do to make this work?
I have an opt 11c rls 25.40?? with pri. I am trying to set up the sets so they have to dial a code to make a ld call.
pick up the handset, dial ld# get stuttered dialtone.
So I have set up aub (clas 000 unr tgar 01 ncos 04 ) and aut (code+ clas 000) in ld 88. I have a telephone that is set up as...
Right! by 10:00 this morning I will need to know everything there is to know about meridian mail. How to program mailboxes, AA greetings and ccr trees It is now 7:30... But wait there's more... I will also need to know how to efficently trouble shoot the thing without manuals or any training...
can you set a 500/2500 analoge station tn to provide or pass "disconnect supervision" the momentary removal of battery from the tn to signal other equipment (ie norstar) that the calling party has hung up? Thanks in advance
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.